Dynamic Forcing of End-Tidal Carbon Dioxide and Oxygen Applied to Functional Magnetic Resonance Imaging

Abstract: Investigations into the blood oxygenation level-dependent (BOLD) functional MRI signal have used respiratory challenges with the aim of probing cerebrovascular physiology. Such challenges have altered the inspired partial pressures of either carbon dioxide or oxygen, typically to a fixed and constant level (fixed inspired challenge (FIC)). The resulting end-tidal gas partial pressures then depend on the subject's metabolism and ventilatory responses. In contrast, dynamic end-tidal forcing (DEF) rapidly and ind… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

7
123
1
1

Year Published

2009
2009
2020
2020

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 117 publications
(132 citation statements)
references
References 40 publications
7
123
1
1
Order By: Relevance
“…The subjects breathed a mixture of oxygen and air, and the end-tidal O 2 partial pressure (P ET O 2 ) was maintained at 225 mmHg by manual control of the gas mixture, by a dedicated experimenter. This achieved similar control over end-tidal gas concentrations as an automated system (Wise et al, 2007).…”
Section: Breathing Systemmentioning
confidence: 72%
“…The subjects breathed a mixture of oxygen and air, and the end-tidal O 2 partial pressure (P ET O 2 ) was maintained at 225 mmHg by manual control of the gas mixture, by a dedicated experimenter. This achieved similar control over end-tidal gas concentrations as an automated system (Wise et al, 2007).…”
Section: Breathing Systemmentioning
confidence: 72%
“…Early methods [15][16][17] focused on maintenance of constant partial pressures using sequential rebreathing approaches, wherein subjects receive an externally administered gas up to a certain flow rate, beyond which they rebreathe expired gas. Feedback approaches have also been explored, 18 although these require extremely high flow rates (e.g., 70 L/min). Slessarev et al 19 have extended the sequential rebreathing approach to incorporate physiologic modeling of CO 2 fluxes in the body to make predictive, breath-by-breath adjustments of inspired gases to achieve prospective and independent control of end-tidal PCO 2 and PO 2 at lower flow rates.…”
Section: Introductionmentioning
confidence: 99%
“…In our design, we bring the bag before the start of the scan and, following the scan, the bag is emptied, folded, and put away. Finally, compared to several other systems 18,21 , the current gas delivery system is simpler, requires less training time, and its consumables are less expensive.…”
Section: Discussionmentioning
confidence: 99%
“…While an exhaustive survey of other gas delivery systems used in the literature is beyond the scope of this article, it is useful to compare the current system to a few commonly used ones 17,18 . A major difference is that our system uses a mouthpiece to deliver the intended gas while most other systems have used a mask in design.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation