2009
DOI: 10.1007/978-1-59745-543-5_13
|View full text |Cite
|
Sign up to set email alerts
|

Dynamic Magnetic Resonance Imaging of Cerebral Blood Flow Using Arterial Spin Labeling

Abstract: Modern functional neuroimaging techniques, including functional MRI, positron emission tomography and optical imaging of intrinsic signals, rely on a tight coupling between neural activity and cerebral blood flow (CBF) to visualize brain activity using CBF as a surrogate marker. Because the spatial and temporal resolution of neuroimaging modalities is ultimately determined by the spatial and temporal specificity of the underlying hemodynamic signals, characterization of the spatial and temporal profiles of the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0
2

Year Published

2011
2011
2021
2021

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(11 citation statements)
references
References 68 publications
0
9
0
2
Order By: Relevance
“…CBF had the lowest detectability, while BOLD had the highest (Table S1). While most rats showed robust BOLD response to all stimulus durations, not all rats presented a detectable CBF response, due to the inherently low SNR of ASL (Detre and Wang, 2002), which is further compromised under the conditions of short TR and thus low labeling efficiency of the DASL sequence utilized here (Silva and Paiva, 2009). For the dosage of iron-oxide particles used (5mg/kg), detectability of the CBV response was between that of the CBF and of the BOLD.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…CBF had the lowest detectability, while BOLD had the highest (Table S1). While most rats showed robust BOLD response to all stimulus durations, not all rats presented a detectable CBF response, due to the inherently low SNR of ASL (Detre and Wang, 2002), which is further compromised under the conditions of short TR and thus low labeling efficiency of the DASL sequence utilized here (Silva and Paiva, 2009). For the dosage of iron-oxide particles used (5mg/kg), detectability of the CBV response was between that of the CBF and of the BOLD.…”
Section: Resultsmentioning
confidence: 99%
“…For simultaneous BOLD-CBF acquisition, a dynamic ASL (DASL) sequence (Barbier et al, 2001; Silva and Paiva, 2009) was employed in which an ASL period of 199.7ms was used and cycles of 120 label images and 120 control images were alternately acquired every 60s. For CBV measurements, 5mg/kg of 30nm ultra-small super-paramagnetic iron oxide (USPIO) particles (Molday ION, Biophysics Assay Laboratory, Inc., Worcester, MA) were injected intravenously to the animal after completion of the BOLD-CBF experiments.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…For many years, these physiological variables could only be measured using radiotracers, i.e., with exposure to ionizing radiation. More recently, advances in fMRI methods allow several hemodynamic and metabolic variables to be quantified without radiation exposure, thereby making them acceptable for routine use in children (Silva & Paiva, 2009). Of these fMRI techniques, CBF as measured by arterial spin labeling (ASL) is the most well validated and widely available.…”
Section: Introductionmentioning
confidence: 99%