2018
DOI: 10.3390/pr6080114
|View full text |Cite
|
Sign up to set email alerts
|

Dynamic Optimization of a Subcritical Steam Power Plant Under Time-Varying Power Load

Abstract: The increasing variability in power plant load in response to a wildly uncertain electricity market and the need to to mitigate CO2 emissions, lead power plant operators to explore advanced options for efficiency optimization. Model-based, system-scale dynamic simulation and optimization are useful tools in this effort and are the subjects of the work presented here. In prior work, a dynamic model validated against steady-state data from a 605 MW subcritical power plant was presented. This power plant model wa… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 15 publications
(11 citation statements)
references
References 37 publications
0
11
0
Order By: Relevance
“…The model was equipped with fuel mass flow-rate characteristics to simulate rapid load changes, boiler equipment failures, and different sliding curves (Figure 6). On the same lines, a dynamic plant operation optimization control system was simulated in [71]. A coal-fired subcritical power plant was modeled in the Modelica ® /Dymola language and Modelon ThermalPower library.…”
Section: Ramping Ratementioning
confidence: 99%
“…The model was equipped with fuel mass flow-rate characteristics to simulate rapid load changes, boiler equipment failures, and different sliding curves (Figure 6). On the same lines, a dynamic plant operation optimization control system was simulated in [71]. A coal-fired subcritical power plant was modeled in the Modelica ® /Dymola language and Modelon ThermalPower library.…”
Section: Ramping Ratementioning
confidence: 99%
“…The dynamic CHP plant model is constructed in the commercial software Dymola [36], which is based on the modeling language Modelica [37], using the component library ThermalPower from Modelon [38], which has been used to model power plants in a number of previous studies [18,19,22,[24][25][26]. The components are modeled based on differential and/or algebraic mass and energy balance equations.…”
Section: Model Descriptionmentioning
confidence: 99%
“…Chen et al [18] developed a dynamic model and studied the implementation of a regulatory control structure in a 605 MW coal-fired plant, followed up by development of dynamic supervisory control schemes for plant efficiency optimization [19]. Coal-fired plant responses to step and ramp changes in load were analyzed by Oko and Wang [20].…”
Section: Introductionmentioning
confidence: 99%
“…In the plant description by Singer [40], only the open-loop configuration is presented (for design analyses). Therefore, common power plant control configurations [43,44] were used in this work, which enabled the study of the closed-loop performance of the plant, as well as the analysis of benefits of supervisory control (based on set-point optimization) presented in Part II of this work [45]. Basic control logic to serve the requirements for dynamic per- Figure 4.…”
Section: Control Structurementioning
confidence: 99%
“…In summary, the model responses to step changes in the coal load illustrate the robustness of the controllers, and the value of the dynamic model of the power plant in tuning the controllers to maintain the regulated variables at set point, even for sudden (and somewhat unrealistic) changes in coal load. This power plant model, validated quantitatively at steady state and qualitatively in terms of closed-loop dynamic performance, can be used as a robust test bed for dynamic simulation and optimization of power plants, which is the focus of Part II of this series[45]. Response of the power plant model with control design to -5%, -10% and -15% step changes in coal load, in terms of (a) T SH , (b) the liquid level of the Drum, (c) the liquid level of the condenser, (d) the liquid level of the deaerator and (e) power generation.…”
mentioning