2008
DOI: 10.1002/lapl.200810026
|View full text |Cite
|
Sign up to set email alerts
|

Dynamic Raman spectroscopy of hydrogen isotopomer mixtures in-line at TILO

Abstract: Abstract:The pure rotational and vibration-rotational Stokes Raman spectra of flowing gaseous mixtures of the hydrogen isotopomers H 2 , HD, and D 2 were measured in order to test the performance of the proposed tritium purity monitoring system designed for the Karlsruhe Tritium Neutrino (KATRIN) mass experiment, which utilises 532 nm CW laser excitation and fibrecoupled scattered light collection, exploiting 90• excitation observation geometry. Short (100-300 s) exposure times were used to simulate the real-t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(19 citation statements)
references
References 19 publications
0
19
0
Order By: Relevance
“…The Raman gas cell is the same cell we have used in all our previous measurements, which is tritium compatible and is based on the design by Taylor et al . For measurements using tritium‐containing isotopologues, the cell has to be placed into a secondary safety enclosure, which requires that the laser beam (and the Raman scattered light) has to pass through additional windows.…”
Section: Methodsmentioning
confidence: 99%
“…The Raman gas cell is the same cell we have used in all our previous measurements, which is tritium compatible and is based on the design by Taylor et al . For measurements using tritium‐containing isotopologues, the cell has to be placed into a secondary safety enclosure, which requires that the laser beam (and the Raman scattered light) has to pass through additional windows.…”
Section: Methodsmentioning
confidence: 99%
“…The different tritiated gas species (T 2 , DT, HT) have to be distinguished not only because of their different properties in the gas dynamical calculations, but also due to their slightly different endpoint energies as well as rotational and vibrational final states. Test measurements with a Raman cell suitable for operation with tritium [118,119] show that a precision of ∆ prec ( T 2 )/ T 2 = 0.1% for T 2 monitoring can be achieved in measurement intervals of < 250 s under KATRIN operating conditions [120,121]. With an optimized setup the acquisition time recently has been reduced to 60 s only.…”
Section: The Wgts Cryostat and Associated Control And Monitoring Systemsmentioning
confidence: 99%
“…The concept of the laser Raman (LARA) monitoring system is shown in Figure 2 . The setup follows closely that originally proposed in the KATRIN Design Report [ 13 ]; its capabilities were successfully demonstrated in 2008 during the “TILO” (Test of Inner LOop) experiment [ 28 ], to ascertain that the inner loop functioned correctly and fulfilled all design specifications. It should be noted that those tests were performed without the WGTS, which was still under construction at that time.…”
Section: Setup and Methodsmentioning
confidence: 99%