2021
DOI: 10.1016/j.actbio.2021.04.055
|View full text |Cite
|
Sign up to set email alerts
|

Dynamically crosslinked polydimethylsiloxane-based polyurethanes with contact-killing antimicrobial properties as implantable alloplasts for urological reconstruction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
28
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 21 publications
(29 citation statements)
references
References 72 publications
1
28
0
Order By: Relevance
“…The doublet peak in the range ∼1700–1730 cm –1 is the characteristic of the carbonyl group, which is absent in the PVDF/BT composite. The band corresponding to the N–H stretching frequency of the amide group was observed at ∼3300 cm –1 in neat TPU . The distinct broadening of the NH peak was observed in the higher frequency regime of 3000–3800 cm –1 (Figure e).…”
Section: Resultsmentioning
confidence: 88%
See 2 more Smart Citations
“…The doublet peak in the range ∼1700–1730 cm –1 is the characteristic of the carbonyl group, which is absent in the PVDF/BT composite. The band corresponding to the N–H stretching frequency of the amide group was observed at ∼3300 cm –1 in neat TPU . The distinct broadening of the NH peak was observed in the higher frequency regime of 3000–3800 cm –1 (Figure e).…”
Section: Resultsmentioning
confidence: 88%
“…The band corresponding to the N−H stretching frequency of the amide group was observed at ∼3300 cm −1 in neat TPU. 24 The distinct broadening of the NH peak was observed in the higher frequency regime of 3000−3800 cm −1 (Figure 1e). The IR bands at ∼1530 and ∼1415 cm −1 are characteristic of C−N and CH 3 bending vibrations, respectively.…”
Section: Resultsmentioning
confidence: 90%
See 1 more Smart Citation
“…The successful integration of varying contents of PDMS within the molten polyurethane matrix has been reported. The antimicrobial composition has been demonstrated to support the growth of the mitochondrially viable and interconnected murine fibroblasts over 7 days in culture [56].…”
Section: Synthetic Scaffoldsmentioning
confidence: 99%
“…Silicones, poly(urethanes), and poly(acrylates) are commonly used for such implants. In the case of monolithic implants, the drug is homogeneously dispersed within the polymer, whereas reservoir-type implants contain a compact drug core with some sort of polymer membrane around it that controls diffusion and the release of the pharmacological compound [306][307][308][309].…”
Section: May the Force Be With You: Mt And Its Implications For Periodontal Regenerationmentioning
confidence: 99%