2012
DOI: 10.1093/ehjci/jer316
|View full text |Cite
|
Sign up to set email alerts
|

EAE/ASE Recommendations for Image Acquisition and Display Using Three-Dimensional Echocardiography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
164
0
8

Year Published

2016
2016
2024
2024

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 488 publications
(173 citation statements)
references
References 153 publications
1
164
0
8
Order By: Relevance
“…Any changes may be detected during a periodic assessment and related with perfusion alterations, or alteration in the patient's clinical state. Volumetric assessment of the left ventricle is facilitated by 3-D TOE because of improved spatial resolution, as well as more accurate and reproducible measurements [21], although a simple measurement of LV areas on a short axis view is usually adequate in the critically-ill patient. LV systolic function is very easily and accurately assessed by an eyeballing evaluation and simple graduation of systolic function in 4 categories, namely supranormal, normal, moderately and severely depressed, allows for treatment adaptation and shock classification.…”
Section: Monitoring Ventricular Functionmentioning
confidence: 99%
“…Any changes may be detected during a periodic assessment and related with perfusion alterations, or alteration in the patient's clinical state. Volumetric assessment of the left ventricle is facilitated by 3-D TOE because of improved spatial resolution, as well as more accurate and reproducible measurements [21], although a simple measurement of LV areas on a short axis view is usually adequate in the critically-ill patient. LV systolic function is very easily and accurately assessed by an eyeballing evaluation and simple graduation of systolic function in 4 categories, namely supranormal, normal, moderately and severely depressed, allows for treatment adaptation and shock classification.…”
Section: Monitoring Ventricular Functionmentioning
confidence: 99%
“…95 Threedimensional echocardiography more accurately assesses the extent of leaflet involvement (since three valve leaflets are simultaneously visualized). 96 Cardiac MRI cine sequences demonstrate similar valve thickening and retraction, reduced excursion and semi-open fixed positions with disease progression (Figure 10). 90 Furthermore, MRI offers the advantage of precise and reproducible functional and anatomical information without the operator dependency of echocardiography.…”
Section: Imaging Featuresmentioning
confidence: 91%
“…A fejlesztések külö-nös szereppel bírnak a veleszületett szívhibák (VSZH) diagnosztikájában elindult alkalmazások terén. Ezek már nemcsak technikai természetűek, de szükséges-sé váltak olyan gyakorlati standardok kidolgozása -amelyek a 2 dimen ziós echokardiográfia (2DE) és felnőtt vonatkozásban már a 3DE-re -is kidolgozásra kerültek (1). Miért is nagy az elvárás a VSZH-k diagnosztikájában a 3DE alkalmazásával szemben?…”
Section: Bevezetésunclassified