2015
DOI: 10.1016/j.urology.2015.06.021
|View full text |Cite
|
Sign up to set email alerts
|

Early Application of Permanent Metallic Mesh Stent in Substitution for Temporary Polymeric Ureteral Stent Reduces Unnecessary Ureteral Procedures in Patients With Malignant Ureteral Obstruction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2015
2015
2018
2018

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 16 publications
(14 citation statements)
references
References 30 publications
0
14
0
Order By: Relevance
“…The studies were published over a period of 23 years (1992–2016) and included 21 prospective and 10 retrospective studies. These studies reported the effectiveness of specific MSs in population studies [1] , [2] , [3] , [5] , [6] , [7] , [8] , [9] , [10] , [11] , [12] , [13] , [14] , [15] , [16] , [17] , [18] , [19] , [20] , [21] , [22] , [23] , [24] , [25] , [26] , [27] , in comparative studies between different MSs [28] and between MSs and JJ stents [29] , [30] . It should be noted that all comparative studies were retrospective in nature.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…The studies were published over a period of 23 years (1992–2016) and included 21 prospective and 10 retrospective studies. These studies reported the effectiveness of specific MSs in population studies [1] , [2] , [3] , [5] , [6] , [7] , [8] , [9] , [10] , [11] , [12] , [13] , [14] , [15] , [16] , [17] , [18] , [19] , [20] , [21] , [22] , [23] , [24] , [25] , [26] , [27] , in comparative studies between different MSs [28] and between MSs and JJ stents [29] , [30] . It should be noted that all comparative studies were retrospective in nature.…”
Section: Resultsmentioning
confidence: 99%
“…Obstruction may be caused either by extension of the disease or by the extrinsic compression of the tumour on the ureter. The decompression of the ureter preserves renal function and prevents the consequences of the obstruction [1] , [2] .…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…39,40 The durability of a metallic US is greater in patients with non-malignant obstructions, and metallic USs have been reported by Wang et al 41 to last up to nine months, and up to five years by Kadlec et al 42 Insertion of a metallic US is recommended in patients that have a greater risk of failure, such as those with malignant obstructions. 43 Despite the durability of the metallic USs, they can present complications in up to half of the patients, especially in patients with advanced stages of cancer. The complications include: abdominal pain, persistent hematuria, severe dysuria, and insufficient drainage.…”
Section: Utility Of Us In Cancer and Resonance Metallic Ureteral Stentmentioning
confidence: 99%