1997
DOI: 10.1302/0301-620x.79b4.7131
|View full text |Cite
|
Sign up to set email alerts
|

Early femoral loosening in one design of cemented hip replacement

Abstract: We have studied aseptic loosening of the femoral component in 76 patients with primary total hip replacement using the Capital prosthesis. The mean follow-up was 26 months (10 to 37). Twelve femoral components (16%) were definitely and eight (10%) were possibly loose. They were characterised by a thin cement mantle (p < 0.001) and excessive residual cancellous bone in the proximomedial region (p < 0.01). We recommend that the cement mantle around the prosthesis should be 2 to 3 mm and that further long-term st… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
31
1
8

Year Published

2000
2000
2017
2017

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 106 publications
(41 citation statements)
references
References 22 publications
1
31
1
8
Order By: Relevance
“…The results of our study contrast reports with cases of early loosening and high loosening rates after cemented implantation of titanium alloy straight femoral prostheses [10,13,18,21]. A mechanism of crevice corrosion has been described as a mechanism of loosening in cemented titanium stems [23].…”
Section: Discussioncontrasting
confidence: 90%
“…The results of our study contrast reports with cases of early loosening and high loosening rates after cemented implantation of titanium alloy straight femoral prostheses [10,13,18,21]. A mechanism of crevice corrosion has been described as a mechanism of loosening in cemented titanium stems [23].…”
Section: Discussioncontrasting
confidence: 90%
“…The poor performance of the modular ti-alloy stem version of the Capital hip (3 M Health Care Ltd, UK) has been reported [22]. The use of inadequately sized broaches resulting in thin cement mantle, along with the mechanical properties and surface texture of the ti-alloy, have been implicated in its failure.…”
Section: Resultsmentioning
confidence: 99%
“…The non-availability of the advanced 4th generation cementation equipment viz. vacuum centrifugal measured pulsed lavage systems did not hamper the results of our series, as none of the cemented femoral stem showed signs of loosening on final follow up however Hunter and Holdsworth [10] reported in 1997 a series with 16% definite and an additional 10% probable loosening of femoral component at 26 months follow up.…”
Section: H) Overall Functional Resultsmentioning
confidence: 56%