2018
DOI: 10.1016/j.ijcard.2017.10.015
|View full text |Cite
|
Sign up to set email alerts
|

Early outcomes of percutaneous pulmonary valve implantation using the Edwards SAPIEN XT transcatheter heart valve system

Abstract: NCT02302131.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
35
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 53 publications
(35 citation statements)
references
References 18 publications
0
35
0
Order By: Relevance
“…During the last decade percutaneous pulmonary valve implantation (PPVI) has been routinely performed in experienced centers and is now considered a safe alternative in selected patients . In the case presented herein, the patient underwent uneventful PPVI.…”
Section: Discussionmentioning
confidence: 94%
See 1 more Smart Citation
“…During the last decade percutaneous pulmonary valve implantation (PPVI) has been routinely performed in experienced centers and is now considered a safe alternative in selected patients . In the case presented herein, the patient underwent uneventful PPVI.…”
Section: Discussionmentioning
confidence: 94%
“…We report a case of an 8 years old boy with double outlet right ventri- Valve distortion can be caused by long-term shear stress and/ or acute chest compression. One additional risk factor is the implantation in proximity to the sternum or in direct opposition to the thoracic aorta [7,13], a common case in PPVI.…”
Section: As E P R Es E N Ta Ti Onmentioning
confidence: 99%
“…Right ventricular outflow tract (RVOT) dysfunction is a common entity found in patients with congenital heart disease and it is defined as RV systolic pressure > 2/3 systemic systolic pressure and/or more‐than‐moderate pulmonary regurgitation. It is most commonly encountered secondary to tetralogy of Fallot but can also be due to truncus arteriosus, a Ross procedure, or less commonly, congenital pulmonary stenosis …”
mentioning
confidence: 99%
“…This necessity led to the invention of the Medtronic Melody valve (Medtronic Inc., Minneapolis, MN) and later the Edwards Sapien and then Sapien XT valves (Edwards Lifesciences Inc., Irvine, CA). Complications of TPVR include stent fracture (mainly of Melody valves implanted without prestenting), conduit rupture, arrhythmias, coronary compression (most often when the valve is placed within a prior bioprosthetic valve), and endocarditis …”
mentioning
confidence: 99%
See 1 more Smart Citation