2000
DOI: 10.1109/23.856572
|View full text |Cite
|
Sign up to set email alerts
|

ECG-gated pinhole SPECT in mice with millimeter spatial resolution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
25
0
2

Year Published

2002
2002
2012
2012

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 57 publications
(28 citation statements)
references
References 15 publications
0
25
0
2
Order By: Relevance
“…1, we see that an image resolution approaching the pinhole diameter can be obtained when the pinhole to detector distance is sufficiently large and the object is close to the pinhole. The smallest pinhole diameters reported so far are about 0.5 mm, and have resulted in a SPET image resolution of about 1 mm [6,7,8].…”
Section: Methodsmentioning
confidence: 97%
See 1 more Smart Citation
“…1, we see that an image resolution approaching the pinhole diameter can be obtained when the pinhole to detector distance is sufficiently large and the object is close to the pinhole. The smallest pinhole diameters reported so far are about 0.5 mm, and have resulted in a SPET image resolution of about 1 mm [6,7,8].…”
Section: Methodsmentioning
confidence: 97%
“…1) offers the ability to obtain high-resolution images of gamma-emitting tracers in small objects like the human thyroid and small animals [6,7,8]. However, a fundamental factor limiting image resolution is the penetration of gammaradiation along the edge of the pinhole collimator.…”
Section: Introductionmentioning
confidence: 98%
“…2) Central pixel of the voxel's projection , which is located where the line passing through the center of the voxel and the center of the pinhole intersects the detection plane. 3) Fraction of activity that reaches the detector, and depends on the voxel position according to (3) where is the effective pinhole diameter, according to Anger [17], is the angle between the line perpendicular to the detector and passing through the pinhole and the line passing through the pinhole and voxel j, and is the distance of the voxel from the plane of the pinhole (we suppose that the voxel is localized at its center) (see [18] for details of (3)). The quantity is also modified by attenuation with a circular symmetric model, assuming a 0.11 uniformly attenuating medium.…”
Section: B Discrete Psf Factorizationmentioning
confidence: 99%
“…This has prohibited in vivo studies of small animals involving disease progression, drug treatment, and genetic modification. In spite of the difficulties in imaging a mouse positioned vertically, SPECT pinhole studies have reported significant spatial resolution [7] and even electrocardiography (ECG)-gated temporal resolution [3]. More recently, micro SPECT cameras have featured a stationary mouse with a rotating camera in order to make in vivo imaging simpler [8].…”
Section: Introductionmentioning
confidence: 98%