2020
DOI: 10.1016/j.jse.2020.07.004
|View full text |Cite
|
Sign up to set email alerts
|

Eclipse stemless shoulder prosthesis vs. Univers II shoulder prosthesis: a multicenter, prospective randomized controlled trial

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
28
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 20 publications
(28 citation statements)
references
References 21 publications
0
28
0
Order By: Relevance
“…16 Regarding the glenoid implant, there was a radiolucent line at the last follow-up in 14.3% of the stemless TSA and 26.7% in the stemmed TSAs, although the difference did not reach statistical significance. 16 Romeo et al 19 did not observe radiolucent lines on follow-up imaging at any time point; however, they noted that this may be due to the relatively short followup period in comparison with studies that described this in stemless designs. 16,35 radiolucency of .2 mm in two shoulders in the stemmed cohort and none in the stemless cohort, but no signs of loosening in either cohort, and concluded that stemless TSA demonstrated noninferiority regarding radiographic outcomes.…”
Section: Radiographic Assessmentsmentioning
confidence: 88%
See 2 more Smart Citations
“…16 Regarding the glenoid implant, there was a radiolucent line at the last follow-up in 14.3% of the stemless TSA and 26.7% in the stemmed TSAs, although the difference did not reach statistical significance. 16 Romeo et al 19 did not observe radiolucent lines on follow-up imaging at any time point; however, they noted that this may be due to the relatively short followup period in comparison with studies that described this in stemless designs. 16,35 radiolucency of .2 mm in two shoulders in the stemmed cohort and none in the stemless cohort, but no signs of loosening in either cohort, and concluded that stemless TSA demonstrated noninferiority regarding radiographic outcomes.…”
Section: Radiographic Assessmentsmentioning
confidence: 88%
“…16 Stemmed implant designs included the Univers II (Arthrex), 16,19 Aequalis, 17 and Comprehensive Mini (Zimmer Biomet). 18 Stemless designs included the Eclipse (Arthrex), 16,19 Aequalis, 17 and Comprehensive Nano (Zimmer Biomet). 18 In all four studies, surgical exposure was achieved through a deltopectoral approach.…”
Section: Study Characteristicsmentioning
confidence: 99%
See 1 more Smart Citation
“…Although our results correspond to previous short-term follow-up studies, clinical outcomes should be interpreted with caution. [9][10][11][12][13][14][15][16] Stemless shoulder systems have been developed in order to reduce stem-related problems, to preserve more bone stock and to make revision surgery less complex. In our study, we reported one revision and no periprosthetic fractures.…”
Section: Discussionmentioning
confidence: 99%
“…Recently, the noninferiority of stemless implants compared with stemmed implants in the short-to mid-term follow-up has been demonstrated in several high-quality studies. [9][10][11][12][13][14][15][16] However, only two studies have been published with a minimum of tenyear follow-up. Magosch et al 17 demonstrated a survival of 96.5% in 75 shoulders.…”
Section: Introductionmentioning
confidence: 99%