Wearable Sensors 2021
DOI: 10.1016/b978-0-12-819246-7.00014-0
|View full text |Cite
|
Sign up to set email alerts
|

Edge algorithms for wearables: an overview of a truly multi-disciplinary problem

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1
1

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 51 publications
0
10
0
Order By: Relevance
“…However, much larger is the impact on the data storage/transmission with 7 data streams from each electrode (1 bio‐potential, 3 accelerometer, 3 gyroscope). The raw bio‐signal data rate is 2,200 bps, while from the IMU it is 21,120 bps, reducing battery life by a factor of approximately 10 [ 34 ]. In practical use a trade‐off between battery lifetime, miniaturisation/size of batteries, and the potential for improved data quality from the incorporation of IMUs is thus required.…”
Section: Resultsmentioning
confidence: 99%
“…However, much larger is the impact on the data storage/transmission with 7 data streams from each electrode (1 bio‐potential, 3 accelerometer, 3 gyroscope). The raw bio‐signal data rate is 2,200 bps, while from the IMU it is 21,120 bps, reducing battery life by a factor of approximately 10 [ 34 ]. In practical use a trade‐off between battery lifetime, miniaturisation/size of batteries, and the potential for improved data quality from the incorporation of IMUs is thus required.…”
Section: Resultsmentioning
confidence: 99%
“…3 increase in height by around 10 µW over the baseline. This potentially could be used in opportunistic transmission [43] as the device can predict that there is a high probability of there being more power available on the hour and wait to do its power-hungry operations (such as wireless transmission [44]) at this point. Comparing this figure to an average of 135 µW over 3.5 ms that is required to transmit a single byte of data on the Bluetooth Low Energy (BLE) Nordic Semiconductor nRF52832 device [45] (assuming V cc = 3.0 V), the energy required for full opportunistic transmissions is some way from being directly realizable.…”
Section: ) Variations In Power Across the Daymentioning
confidence: 99%
“…Connected cables yield a bulky BMI setup limiting subjects' degrees of movement freedom. While wireless technology allows better user comfort, it introduces major drawbacks such as short battery life and privacy concerns [8]. Moreover, offline analysis leads to long delays in the information extraction.…”
Section: Introductionmentioning
confidence: 99%
“…However, many challenges need to be addressed in edge processing for BMI devices. Analyzing a large amount of sensor data at the edge requires miniaturized processing engines that provide enough compute power to extract useful information in real-time, while at the same time consume low power and are energy-efficient for a prolonged battery life [8]. A popular family of microcontroller units (MCUs) is the ARM Cortex-M series.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation