2015
DOI: 10.1155/2015/232381
|View full text |Cite
|
Sign up to set email alerts
|

EEG Signals Analysis Using Multiscale Entropy for Depth of Anesthesia Monitoring during Surgery through Artificial Neural Networks

Abstract: In order to build a reliable index to monitor the depth of anesthesia (DOA), many algorithms have been proposed in recent years, one of which is sample entropy (SampEn), a commonly used and important tool to measure the regularity of data series. However, SampEn only estimates the complexity of signals on one time scale. In this study, a new approach is introduced using multiscale entropy (MSE) considering the structure information over different time scales. The entropy values over different time scales calcu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
27
0
1

Year Published

2016
2016
2021
2021

Publication Types

Select...
6
1
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 41 publications
(31 citation statements)
references
References 52 publications
0
27
0
1
Order By: Relevance
“…Previous studies have found distinct results for different scales in MSE and suggested that a single scale is not enough for the analysis of biological signals [36,38,40,54,113,127,128]. However, the interpretation of the biological mechanisms reflected by multiple scales has not been well-established.…”
Section: Entropy With Multiple Scales Corresponding To Various Rangesmentioning
confidence: 99%
“…Previous studies have found distinct results for different scales in MSE and suggested that a single scale is not enough for the analysis of biological signals [36,38,40,54,113,127,128]. However, the interpretation of the biological mechanisms reflected by multiple scales has not been well-established.…”
Section: Entropy With Multiple Scales Corresponding To Various Rangesmentioning
confidence: 99%
“…These are three commonly used anaesthetics based on the same mechanisms of action via γ-aminobutyric acid type A (GABAA) receptor [41]. Previous studies have illustrated that propofol is not significantly different from sevoflurane or desflurane for general anaesthesia [42][43][44].…”
Section: Real Eeg Datasetmentioning
confidence: 99%
“…That is why EEG signals have been widely used as a powerful tool to capture the information about anaesthetic depth. As a result, many techniques for DoA estimation have been developed based on EEG signals [16][17][18][19][20]. Among the many DoA monitoring devices, the Bispectral index (BIS), developed in 1992 by Aspect Medical Systems [21,22], is the most popular.…”
Section: Introductionmentioning
confidence: 99%