2012
DOI: 10.21168/rbrh.v17n2.p87-100
|View full text |Cite
|
Sign up to set email alerts
|

Efeito de Escala nos Valores de Pressão Média junto ao Fundo em Bacias de Dissipação por Ressalto Hidráulico Submergido

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
48
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(52 citation statements)
references
References 0 publications
2
48
0
Order By: Relevance
“…To analyze the effect of possible errors of measurement of extreme pressures commonly adopted in projects (P 0.1% and P 99.9% ), due to the uncertainties in the position of the transducer in the steps, experimental data of pressure measured with transducers by Sanagiotto & Marques (2008) were used in this study. The standard deviation values (σ d ) and statistical probability distribution coefficients N 0.1% and N 99.9% were calculated, respectively, using Equations 11 and 12, following the same methodology used in studies of extreme pressures in hydraulic jumps (Novakoski et al, 2017b;Teixeira, 2008…”
Section: Discussionmentioning
confidence: 99%
“…To analyze the effect of possible errors of measurement of extreme pressures commonly adopted in projects (P 0.1% and P 99.9% ), due to the uncertainties in the position of the transducer in the steps, experimental data of pressure measured with transducers by Sanagiotto & Marques (2008) were used in this study. The standard deviation values (σ d ) and statistical probability distribution coefficients N 0.1% and N 99.9% were calculated, respectively, using Equations 11 and 12, following the same methodology used in studies of extreme pressures in hydraulic jumps (Novakoski et al, 2017b;Teixeira, 2008…”
Section: Discussionmentioning
confidence: 99%
“…For the validation of the pressure forecasting methodology proposed by Teixeira (2003) for the low Froude number application, a two-dimensional model of the discharge system of Santo Antônio HPP was built in order to collect instantaneous sample pressure data. This model was built in the Laboratório de Hidráulica Experimental e Recursos Hídricos (LAHE) of ELETROBRÁS-FURNAS (LAHE/FURNAS) in Brazil.…”
Section: Methodsmentioning
confidence: 99%
“…Thus, this paper aims to validate the extreme pressure forecasting method provided by Teixeira (2003) on its application for low Froude number situations.…”
Section: /10mentioning
confidence: 99%
See 2 more Smart Citations