Effect of airway device and depth of anesthesia on intra-ocular pressure measurement during general anesthesia in children

Abstract: Background and Aims: Accurate measurement of intraocular pressure (IOP) under anaesthesia is essential for diagnosis and further management of pediatric glaucoma patients. However, depth of anaesthesia and use of airway device like laryngeal mask airway (LMA) or endotracheal tube can influence IOP values measured. We planned this study to compare change of IOP with facemask or LMA. Change of IOP at varying depth of anaesthesia was also assessed. Material and Methods: Af… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(1 citation statement)
references
References 17 publications
0
1
0
Order By: Relevance
“…A single observer performed examinations under general sevoflurane anesthesia using spontaneous ventilation [ 17 ]. All patients underwent complete preoperative ocular examinations including IOP measurement using Tono-Pen XL (Medtronic Solan, Jacksonville, FL, USA), corneal diameter measurement using a caliper, gonioscopy using a Koeppe goniolens (17 – 18 mm; Ocular Instruments, Inc., Bellevue, WA) under the operating microscope (all included corneas had adequate clarity to perform gonioscopy), optic disc evaluation using direct (Keeler, PA, USA) and indirect (Heine, Germany) ophthalmoscopy, and axial length measurement using A-scan ultrasonography (Quantel Medical and Lumibird Medical, France).…”
Section: Methodsmentioning
confidence: 99%
“…A single observer performed examinations under general sevoflurane anesthesia using spontaneous ventilation [ 17 ]. All patients underwent complete preoperative ocular examinations including IOP measurement using Tono-Pen XL (Medtronic Solan, Jacksonville, FL, USA), corneal diameter measurement using a caliper, gonioscopy using a Koeppe goniolens (17 – 18 mm; Ocular Instruments, Inc., Bellevue, WA) under the operating microscope (all included corneas had adequate clarity to perform gonioscopy), optic disc evaluation using direct (Keeler, PA, USA) and indirect (Heine, Germany) ophthalmoscopy, and axial length measurement using A-scan ultrasonography (Quantel Medical and Lumibird Medical, France).…”
Section: Methodsmentioning
confidence: 99%