2021
DOI: 10.1016/j.molliq.2020.114944
|View full text |Cite
|
Sign up to set email alerts
|

Effect of alkyl chain length on the extraction properties of U and Th using novel CnmimNTf2/isophthalamide systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
9

Relationship

4
5

Authors

Journals

citations
Cited by 16 publications
(11 citation statements)
references
References 64 publications
0
11
0
Order By: Relevance
“…[17][18][19][20] The variation in the structural properties of the cations of ionic liquids results in the modification of the extraction mechanism, speciation and kinetics of mass transfer. [21][22][23][24] For same metal-ligand systems, changing the cations in the ionic liquids can induce 'cation exchange', 'anion exchange' and 'solvation' mechanisms involving different extracted species. 25 Although the application of ionic liquids generally improves the extraction efficiency by many folds compared to molecular diluents, a few cases have been reported in the literature, where there was no improvement in the distribution ratio values (D) of the metal ions.…”
Section: Introductionmentioning
confidence: 99%
“…[17][18][19][20] The variation in the structural properties of the cations of ionic liquids results in the modification of the extraction mechanism, speciation and kinetics of mass transfer. [21][22][23][24] For same metal-ligand systems, changing the cations in the ionic liquids can induce 'cation exchange', 'anion exchange' and 'solvation' mechanisms involving different extracted species. 25 Although the application of ionic liquids generally improves the extraction efficiency by many folds compared to molecular diluents, a few cases have been reported in the literature, where there was no improvement in the distribution ratio values (D) of the metal ions.…”
Section: Introductionmentioning
confidence: 99%
“…Due to the presence of the longer n-octyl chain as compared to the n-butyl group, the aqueous solubility of the C 8 mim + ion is considered to be lower as compared to that of the C 4 mim + ion which can explain the observed behavior. 52 Figure 3d shows the typical EDXRF spectra of the aqueous phase prior and after the extraction of Nb and Ta using 100 mM of the FIL in C 4 mim•NTf 2 and C 8 mim•NTf 2 . The Nb amount was monitored using the K α ray at 16.594 keV, whereas, for Ta, the L α line at 8.114 keV was chosen.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…During the cation exchange mechanism, since the metal–ligand complex species is cationic in nature, charge neutrality after mass transfer is being maintained by an exchange of equivalent amount of the methylimidazolium ion from the ionic liquid phase to the aqueous phase. Due to the presence of the longer n -octyl chain as compared to the n -butyl group, the aqueous solubility of the C 8 mim + ion is considered to be lower as compared to that of the C 4 mim + ion which can explain the observed behavior …”
Section: Resultsmentioning
confidence: 99%
“…These ligands were synthesized and characterized, as described in the literature. , The general procedure for synthesizing ligands involves a two-step reaction [Figure ]. Initially, thionyl chloride (40 mmol, 2.90 mL) was added to 5-bromoisophthalic acid (2 mmol, 0.490 g), and the suspension was refluxed under a nitrogen atmosphere for 16 h to give a clear solution.…”
Section: Methodsmentioning
confidence: 99%