Effect of Aortic Wall Deformation with Healthy and Calcified Annulus on Hemodynamic Performance of Implanted On-X Valve

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
14
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(14 citation statements)
references
References 37 publications
0
14
0
Order By: Relevance
“…Concerning the geometrical modelling of the BMAV, in the majority of FSI studies the device’s geometry was reconstructed to replicate commercially available designs, such as the Bicarbon valve (Corcym Srl, Milan, IT) ( 58 , 59 , 67 , 71 ), the ATS Open Pivot valve (Medtronic, Dublin, IR) ( 54 56 , 63 , 75 , 79 ), the On-X valve (Artivion, Kennesaw, GA, USA) ( 38 , 45 ) and valves from St. Jude series (Abbott Laboratories, Chicago, IL, USA) ( 27 , 28 , 31 , 33 , 35 , 37 , 49 53 , 57 , 60 62 , 64 66 , 68 70 , 72 77 , 81 – 85 ). Nevertheless, idealized valve models, which do not refer to specific commercial designs, are sometimes considered ( Figure 2C ) ( 42 ).…”
Section: State Of the Art Of Fsi Simulation Of Mechanical Aortic Valvesmentioning
confidence: 99%
See 3 more Smart Citations
“…Concerning the geometrical modelling of the BMAV, in the majority of FSI studies the device’s geometry was reconstructed to replicate commercially available designs, such as the Bicarbon valve (Corcym Srl, Milan, IT) ( 58 , 59 , 67 , 71 ), the ATS Open Pivot valve (Medtronic, Dublin, IR) ( 54 56 , 63 , 75 , 79 ), the On-X valve (Artivion, Kennesaw, GA, USA) ( 38 , 45 ) and valves from St. Jude series (Abbott Laboratories, Chicago, IL, USA) ( 27 , 28 , 31 , 33 , 35 , 37 , 49 53 , 57 , 60 62 , 64 66 , 68 70 , 72 77 , 81 – 85 ). Nevertheless, idealized valve models, which do not refer to specific commercial designs, are sometimes considered ( Figure 2C ) ( 42 ).…”
Section: State Of the Art Of Fsi Simulation Of Mechanical Aortic Valvesmentioning
confidence: 99%
“…Additionally, different levels of detail can be adopted to model the hinges connecting valve leaflets and the housing. The hinge recess of the housing can be reproduced with a realistic geometry, featuring a characteristic butterfly shape ( 28 , 33 , 37 , 38 , 45 , 47 , 48 , 60 , 75 ). Alternatively, the coupling between the leaflets and the housing can be simplified, for example, by replacing the hinge with a peripheral gap ( 27 , 46 , 58 , 67 ) or modelling a simplified pin ( 41 ) or spherical ( 72 , 81 ) hinge.…”
Section: State Of the Art Of Fsi Simulation Of Mechanical Aortic Valvesmentioning
confidence: 99%
See 2 more Smart Citations
“…Smart Materials can reform from their temporary shape to their original one in response to an external stimulus such as temperature, light, magnetic field, electrical potential, and pH (Janbaz et al, 2016;Abdolahi et al, 2017;Roudbarian et al, 2019a). These materials have myriad applications in different fields, such as aerospace engineering (Liu et al, 2014), robotics (Jebellat et al, 2021;Jin et al, 2018), textile engineering (Zhang et al, 2018;Udhayaraman and Mulay, 2019), medical devices (Zhao et al, 2019;Sadipour et al, 2020), drug delivery (Gharehnazifam et al, 2021(Gharehnazifam et al, , 2022Bayat et al, 2020), and biomaterials (Janbaz et al, 2016;Asadzadeh et al, 2020). Among them, shape-memory polymer (SMP) is a type of smart material that can intake shape-memory effect (SME).…”
Section: Introductionmentioning
confidence: 99%