Effect of Axial Clearance Variation on Dual-Rotor Flowmeter Performance
Fuji Huang,
Liang Yan,
Chabi Christian Monsia
et al.
Abstract:This study examines the impact of axial clearance variations on the performance characteristics of a dual-rotor flowmeter (DRT-FM) through numerical simulations, with the validity of the numerical results verified by calibration experiments. The results indicate that within the range of 200 L/h to 1600 L/h, the K factors of different groups increase as clearance increases. The K factor of the 0.80 mm group is the largest, showing an average increase of around 6% compared to that of the 0.50 mm group. Additiona… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.