Effect of Calcium on Lead in Soft-Water Distribution Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
6
0

Year Published

2007
2007
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(7 citation statements)
references
References 8 publications
0
6
0
Order By: Relevance
“…28 This relationship was not found in the current study, most likely due to different background water quality, although the large range of hardness to alkalinity ratios in the synthetic waters may also have played a role. Bisogni et al 31 found that at a concentration of 5 mg L −1 , calcium destabilized colloidal lead particles by altering the zeta potential. However, increasing the calcium concentration from 5 to 40 mg L −1 did not provide any additional benefit, 31 which may explain why this was not observed in the present study.…”
Section: Impact Of Water Quality Factors On Galvanic Corrosionmentioning
confidence: 99%
See 2 more Smart Citations
“…28 This relationship was not found in the current study, most likely due to different background water quality, although the large range of hardness to alkalinity ratios in the synthetic waters may also have played a role. Bisogni et al 31 found that at a concentration of 5 mg L −1 , calcium destabilized colloidal lead particles by altering the zeta potential. However, increasing the calcium concentration from 5 to 40 mg L −1 did not provide any additional benefit, 31 which may explain why this was not observed in the present study.…”
Section: Impact Of Water Quality Factors On Galvanic Corrosionmentioning
confidence: 99%
“…Bisogni et al 31 found that at a concentration of 5 mg L −1 , calcium destabilized colloidal lead particles by altering the zeta potential. However, increasing the calcium concentration from 5 to 40 mg L −1 did not provide any additional benefit, 31 which may explain why this was not observed in the present study.…”
Section: Impact Of Water Quality Factors On Galvanic Corrosionmentioning
confidence: 99%
See 1 more Smart Citation
“…“Flaking lead” particles larger than 12 μm associated with scale detaching from a pipe were observed, along with colloidal lead fractions associated with iron oxides and humic acids (De Mora et al, 1987; Hulsmann, 1990). Particulate lead was clearly demonstrated to come from solder lead–tin joints in pipe rigs (Bisogni et al, 2000), and a small survey of lead in potable water from around the United States revealed numerous instances in which most of the lead was present as particulates (sometimes ≥ 1,000 μg/L Pb) in first‐draw tap samples (McNeill and Edwards, 2004).…”
mentioning
confidence: 99%
“…However, given the practically universal coexistence of PbO 2 and Pb(II) minerals in corrosion scales , , it is unclear to what extent Pb(II) minerals need to be oxidized to effectively control lead release. On the other hand, a significant portion of Pb release, notably that during the Washington, DC event, is associated with colloidal particles with varying sizes . Relative contributions of Pb(II) and Pb(IV) species in the structures of submicron particles that constitute particulate lead have not been ascertained.…”
Section: Introductionmentioning