1994
DOI: 10.1016/0109-5641(94)90028-0
|View full text |Cite
|
Sign up to set email alerts
|

Effect of cement film thickness on the fracture resistance of a machinable glass-ceramic

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

6
64
1
10

Year Published

2002
2002
2014
2014

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 98 publications
(81 citation statements)
references
References 5 publications
6
64
1
10
Order By: Relevance
“…To isolate the final surface finishing method and type of ceramic material as the only variables in this study, a simple experimental design was adopted whereby rectangular ceramic plates adhesively luted to dentin were loaded with pressure only at one point at the center. Although this experimental design was also adopted in previous studies 17,19) , further studies are required to verify if different test methods would yield consistent results.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…To isolate the final surface finishing method and type of ceramic material as the only variables in this study, a simple experimental design was adopted whereby rectangular ceramic plates adhesively luted to dentin were loaded with pressure only at one point at the center. Although this experimental design was also adopted in previous studies 17,19) , further studies are required to verify if different test methods would yield consistent results.…”
Section: Discussionmentioning
confidence: 99%
“…In a bid to improve the fracture strength, studies on this issue have identified several factors that influence the fracture resistance of all-ceramic restorations, namely, type of ceramic material [2][3][4][5][6] , surface finish of all-ceramic restoration 2,[7][8][9][10][11][12][13][14][15][16] , cement thickness [17][18][19] , and type of luting agent 3,[20][21][22][23][24][25] . On the preferred surface treatment for ceramic restorations, glazing is generally advocated to improve their strength 2,12,13,26,27) and reduce their surface roughness 12,16,26,[28][29][30] .…”
Section: Introductionmentioning
confidence: 99%
“…Currently, the restorations for fracture load tests are differently cemented in various studies [1][2][3][4] . Zinc oxide-phosphate, glass ionomer or adhesive cements are used [1][2][3][4][5][6][7][8] . Zirconia shows high values of flexural strength 9) ; lithium disilicate exhibits lower flexural strength than zirconia 10) .…”
Section: Introductionmentioning
confidence: 99%
“…Unfortunately, there is a lack of studies on damage propagation in dental ceramic structures supported by dentin. All-ceramic restorations should be firmly bonded to the underlying tooth structure with a luting agent to improve fracture resistance 15) . Recent studies have further demonstrated that luting agents restricted and resisted against the propagation of cracks from the internal surface of the bonded resin 15,16) .…”
Section: Introductionmentioning
confidence: 99%
“…All-ceramic restorations should be firmly bonded to the underlying tooth structure with a luting agent to improve fracture resistance 15) . Recent studies have further demonstrated that luting agents restricted and resisted against the propagation of cracks from the internal surface of the bonded resin 15,16) . Although there is evidence-based data for the effect of luting agents on all-ceramic crowns 17,18) , the thickness effect of each layer in ceramic-cementdentin structures is not well studied.…”
Section: Introductionmentioning
confidence: 99%