2015
DOI: 10.1016/j.ijporl.2015.02.008
|View full text |Cite
|
Sign up to set email alerts
|

Effect of cochlear implant electrode array design on auditory nerve and behavioral response in children

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

5
16
0
1

Year Published

2016
2016
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 28 publications
(22 citation statements)
references
References 24 publications
5
16
0
1
Order By: Relevance
“…Intra-operative ECAP thresholds were significantly lower for the apical electrodes than those at the base. This has been observed in many other studies (Gordin et al, 2009;Lathuilliere et al, 2017;Spivak et al, 2011;Telmesani and Said, 2015), and may be due to differences between the apex and base in neuronal survival or density (Lai and Dillier 2009;Polak et al 2004). There have been some suggestions that the radial distance between the modiolar wall and the electrode may also be a factor (Saunders et al, 2002;Spivak et al 2011).…”
Section: Discussionsupporting
confidence: 53%
See 1 more Smart Citation
“…Intra-operative ECAP thresholds were significantly lower for the apical electrodes than those at the base. This has been observed in many other studies (Gordin et al, 2009;Lathuilliere et al, 2017;Spivak et al, 2011;Telmesani and Said, 2015), and may be due to differences between the apex and base in neuronal survival or density (Lai and Dillier 2009;Polak et al 2004). There have been some suggestions that the radial distance between the modiolar wall and the electrode may also be a factor (Saunders et al, 2002;Spivak et al 2011).…”
Section: Discussionsupporting
confidence: 53%
“…The threshold of the evoked response represents the lowest current level required to stimulate cochlear neural elements and depends on many factors, including the scalar position of the stimulating electrodes. Some studies have shown that it can even be used as an indicator for translocation of the electrode array into the scala vestibuli, and electrode position within the scala tympani (ST), with lower ECAP thresholds in perimodiolar arrays compared with straight arrays (Mittman et al, 2015;Muller et al, 2015;Poley et al, 2015;Telmesani and Said, 2015;Venail et al, 2015). It is important that the electrode is inserted into the correct scala, as the insertion of the array into the ST without dislocation into the scala vestibuli has been associated with better speech perception outcomes (Aschendorff et al, 2007;Carlson et al, 2011;Finley et al, 2008).…”
Section: Introductionmentioning
confidence: 99%
“…Several studies have demonstrated lower stimulation thresholds for permodiolar arrays than for straight arrays, either when measured psychophysically or when assessed by objective measures [Cohen et al, 2001;Gordin et al, 2009;Runge-Samuelson et al, 2009;Jeong et al, 2015;Müller et al, 2015;Telmesani and Said, 2015]. Other studies have reported a reduced spread of excitation using forward masking ECAP paradigms [Hughes and Abbas, 2006;Basta et al, 2010;Hughes and Stille, 2010] with improved spectral discrimination.…”
Section: Introductionmentioning
confidence: 99%
“…The electrically evoked compound action potential (ECAP) has been widely used as a valuable objective tool in mapping the CI, especially for those who have difficulty in showing the reliable behavioral response [12]. Whereas some studies reported that the ECAP threshold, T level, and C level were lower for the PM than the LW, and were lower on the apical region than on the basal and medial regions [13-15], other studies showed different results [16,17]. These contrasting results may be because only a small number of subjects or subjects with much heterogeneity participated, only several electrode contacts were selected to represent the electrode site, and more recent LWs were included or exclude in the studies.…”
Section: Introductionmentioning
confidence: 99%