Effect of Different Bar Designs on Axial and Nonaxial Retention Forces of Implant-Retained Maxillary Overdentures: An In Vitro Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(14 citation statements)
references
References 20 publications
0
10
0
1
Order By: Relevance
“…For patients with extensive residual ridge resorption, the replacement of hard and soft tissues with a removable denture may be a more suitable option than the use of a cemented (or fixed type) restoration [1–4]. The analysis and management of the restorative space in edentulous patients with implant overdentures are important for the planning of implant placement and for the design of the denture [16, 19, 20].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…For patients with extensive residual ridge resorption, the replacement of hard and soft tissues with a removable denture may be a more suitable option than the use of a cemented (or fixed type) restoration [1–4]. The analysis and management of the restorative space in edentulous patients with implant overdentures are important for the planning of implant placement and for the design of the denture [16, 19, 20].…”
Section: Discussionmentioning
confidence: 99%
“…Denture teeth (SR; Ivoclar Vivadent, Ellwangen, Germany) were set and tried in before the finishing process. The denture was finished with the use of an autopolymerizing acrylic resin base material (PalaXpress Ultra; Heraeus Kulzer; Germany) and delivered back to the office on the same day (Figures 10–12) [1–4, 17, 18].…”
Section: Casementioning
confidence: 99%
See 1 more Smart Citation
“…These 2 types of bars have poor retention in case of lateral forces. 5 Dos Santos MBF. et al demonstrated that a round section bar exerts less tension on the « clips» and prosthetic screws than the Hader bar.…”
Section: Clinical Case Nomentioning
confidence: 99%
“…Isırma kuvvetleri benzer bulunmuĢ, ancak ataçmanlı bar ile oluĢturulan protezde oblik kuvvetler daha fazla görül-müĢ ve daha fazla komplikasyon bildirilmiĢtir. Elsyad ve arkadaĢları 17 , farklı bar dizaynlarının retansiyonunu in vitro olarak kıyasladıkları çalıĢmada Hader bar sisteminin, Dolder bar ve millenmiĢ bar sitemine kıyasla maksiller implant destekli overdenture uygulamalarında aksiyal kuvvetlere karĢı daha iyi retansiyon gösterdiğini bildirmiĢlerdir. Toio ve arkadaĢları 18 , millenmiĢ bar uyguladıkları protez hastalarının 2 yıl takibi sonucunda vida gevĢemesi, vida kırılması, bar kırılması, protez kaidesinin kırılması ve protez kaidesinden diĢin ayrılması gibi komplikasyonlar bildirmiĢlerdir.…”
Section: Bar Tutucularunclassified