2009
DOI: 10.1016/j.physe.2008.10.018
|View full text |Cite
|
Sign up to set email alerts
|

Effect of electrode configuration on capacitive humidity sensitivity of silicon nanoporous pillar array

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2009
2009
2018
2018

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 17 publications
0
3
0
Order By: Relevance
“…J. Zhang's group had designed and fabricated capacitive humidity sensors based on Ni/SiNWs nanocomposites, which exhibited improved performance compared with the sensors made from SiNWs [52,53]. X. Li's group fabricated two humidity sensors based on silicon nanoporous pillar array (Si-NPA) by evaporating two-side comb electrodes and coplanar interdigital electrodes, and the experimental results showed that the sensor with coplanar interdigital electrodes exhibits higher sensitivity than that with two-side comb electrodes [54][55][56].…”
mentioning
confidence: 99%
“…J. Zhang's group had designed and fabricated capacitive humidity sensors based on Ni/SiNWs nanocomposites, which exhibited improved performance compared with the sensors made from SiNWs [52,53]. X. Li's group fabricated two humidity sensors based on silicon nanoporous pillar array (Si-NPA) by evaporating two-side comb electrodes and coplanar interdigital electrodes, and the experimental results showed that the sensor with coplanar interdigital electrodes exhibits higher sensitivity than that with two-side comb electrodes [54][55][56].…”
mentioning
confidence: 99%
“…And a lot of research based on their performance has been realized; as on their use as capacitive, inductive, 88 humidity system dielectric, piezoacoustic, chemical, biological, and microelectromechanical interdigital sensors and transducers [102]. There are also some poor research about the interdigital electrode dimensions and configurations [103,104] and therefore an extended research on the optimization of shape and dimensions would be innovative. A part of coplanar interdigital electrodes the next more used shape is the concentric electrode.…”
Section: State Of the Art And Proposed Solutionmentioning
confidence: 99%
“…And lot of research based on their performance has been realized [76]. There are also some research about the interdigital electrode dimensions and configurations [103,104] very limited by their specific use and difficult replication. Therefore, an extended research on the specific optimization of shape and dimensions would be innovative.…”
Section: Single-layer Coplanar Capacitive Electrodesmentioning
confidence: 99%