2011
DOI: 10.1016/j.mseb.2011.02.031
|View full text |Cite
|
Sign up to set email alerts
|

Effect of electrodeposition current density on the microstructure and the degradation of electroformed iron for degradable stents

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
25
0
1

Year Published

2013
2013
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 60 publications
(26 citation statements)
references
References 31 publications
0
25
0
1
Order By: Relevance
“…Annealing reduces imperfection density and therefore might reduce the corrosion rates of iron based alloys which has already been reported to be the answer for the corrosion rate reduction of annealed pure Fe in Hanks' solution [3,38,39]. Consequently, UD samples have a more retained amount of residual stress and degraded slightly faster than BD annealed ones.…”
Section: Biodegradation Behaviourmentioning
confidence: 99%
“…Annealing reduces imperfection density and therefore might reduce the corrosion rates of iron based alloys which has already been reported to be the answer for the corrosion rate reduction of annealed pure Fe in Hanks' solution [3,38,39]. Consequently, UD samples have a more retained amount of residual stress and degraded slightly faster than BD annealed ones.…”
Section: Biodegradation Behaviourmentioning
confidence: 99%
“…Texture plots and corresponding contour intervals were obtained using a harmonic series expansion calculation. The normalised texture intensities are expressed in terms of Multiples of Uniform Distribution (MUD) [34]. Both methods provide the user with an indication of the orientation relationship between two coordinate systems: sample and crystal.…”
Section: Electron Backscatter Diffractionmentioning
confidence: 99%
“…Previously,w ed evelopedalaser based( two-photon polymerization-based) fabrication technique for making hollow polymer microneedles [27].T he advantageo ft his over conventional lithographyi st hat ad esign can be created in Solidworks and 3D structures can be directly fabricated without am ask or wet chemical etching processes. While highly reproducibles tructures are readily made with this technique,t he materials usedi nt wo-photon polymerization are largelyl imited to photo-cured polymers or photo-reduced metals that lack the mechanical properties of bulk metals.W eo ften observed microneedle tip deformationw ith repeated ex vivo insertionso ft he uncoatede -Shell 300 microneedle into porcine skin, especially with the largeri nternalb ore dimensions (~200 microns) necessary to increase the extraction volume for sensing.…”
Section: Resultsmentioning
confidence: 99%