2014
DOI: 10.1016/j.ijheatmasstransfer.2014.05.044
|View full text |Cite
|
Sign up to set email alerts
|

Effect of evaporator tilt on the operating temperature of a loop heat pipe without a secondary wick

Abstract: Abstract:The effect of evaporator tilt on the operating temperature of a loop heat pipe (LHP) without a secondary wick under terrestrial surroundings was investigated both experimentally and theoretically in this work. The experiments were conducted with the evaporator placed at three different tilts: (i) the evaporator was horizontal with the compensation chamber (CC), (iii) the evaporator was vertically below the CC, and (iii) the evaporator was higher the CC with a tilt angle of xx. The experimental results… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 21 publications
(4 citation statements)
references
References 34 publications
0
4
0
Order By: Relevance
“…Another noteworthy phenomenon was that the increase of evaporator outlet temperature caused by adverse tilt in this paper was only about 7 C (as illustrated by Fig. 9), which was much lower than that in Ref [20]. This might be related to the installation of secondary wick in evaporator core and CC.…”
Section: Horizontal Attitude ( =0)mentioning
confidence: 57%
See 2 more Smart Citations
“…Another noteworthy phenomenon was that the increase of evaporator outlet temperature caused by adverse tilt in this paper was only about 7 C (as illustrated by Fig. 9), which was much lower than that in Ref [20]. This might be related to the installation of secondary wick in evaporator core and CC.…”
Section: Horizontal Attitude ( =0)mentioning
confidence: 57%
“…Recently, LHP technology has been developed for aircraft applications and the gas/liquid distribution in LHP would be affected significantly by gravity, which is quite different from the case in space [19,20]. It seems that the relative position between evaporator and CC has much great impacts on the performance of LHP because the tilt of evaporator could change the heat and mass transfer process in evaporator and CC significantly.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The tilt of evaporator changes the relative height of evaporator and CC, which affects the liquid-vapor distribution and heat transfer in CC. Since the operating temperature is usually determined by the energy balance of CC [1], the evaporator tilt will eventually have a significant impact on the LHP operating characteristics, as reported by Ref [15]. Besides, the elevation of evaporator or condenser also has a great effect on the LHP operation because of the action of liquid head in the gravitational field [14,16].…”
Section: Introductionmentioning