2018
DOI: 10.1016/j.prosdent.2017.11.003
|View full text |Cite
|
Sign up to set email alerts
|

Effect of feldspathic porcelain layering on the marginal fit of zirconia and titanium complete-arch fixed implant-supported frameworks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
40
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 16 publications
(40 citation statements)
references
References 38 publications
0
40
0
Order By: Relevance
“…In the included publications, more than half (27 out of 47 articles) described the implant‐framework misfit with 2D measurements, such as vertical (31 articles) 4,17‐45 and horizontal gaps (4 articles) at the margin, 18,43,44 as well as internal gaps between the mating surfaces (4 articles), 19‐21,46 by stereomicroscope and SEM in different experimental conditions (one‐screw test and definitive‐fit test). Besides, 18 articles demonstrated the implant framework misfit with 3D measurements, 6,18,22,38,42,45,47‐58 including the volumetric discrepancy 58 and spatial deviation in X ‐, Y ‐, and Z ‐axis 6,45,47,48,50,51,54‐56 . The 3D data acquisition was usually performed by optical or tactile scanning, 42,56‐58 computerized tomography (CT), 6,18,22,52,53,59 and coordinate measuring machine (CMM) 22,38,47‐51,54‐56 .…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…In the included publications, more than half (27 out of 47 articles) described the implant‐framework misfit with 2D measurements, such as vertical (31 articles) 4,17‐45 and horizontal gaps (4 articles) at the margin, 18,43,44 as well as internal gaps between the mating surfaces (4 articles), 19‐21,46 by stereomicroscope and SEM in different experimental conditions (one‐screw test and definitive‐fit test). Besides, 18 articles demonstrated the implant framework misfit with 3D measurements, 6,18,22,38,42,45,47‐58 including the volumetric discrepancy 58 and spatial deviation in X ‐, Y ‐, and Z ‐axis 6,45,47,48,50,51,54‐56 . The 3D data acquisition was usually performed by optical or tactile scanning, 42,56‐58 computerized tomography (CT), 6,18,22,52,53,59 and coordinate measuring machine (CMM) 22,38,47‐51,54‐56 .…”
Section: Resultsmentioning
confidence: 99%
“…Besides, 18 articles demonstrated the implant framework misfit with 3D measurements, 6,18,22,38,42,45,47‐58 including the volumetric discrepancy 58 and spatial deviation in X ‐, Y ‐, and Z ‐axis 6,45,47,48,50,51,54‐56 . The 3D data acquisition was usually performed by optical or tactile scanning, 42,56‐58 computerized tomography (CT), 6,18,22,52,53,59 and coordinate measuring machine (CMM) 22,38,47‐51,54‐56 . The advantages, disadvantages and accuracy of different acquisition methods are listed in Table 4.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Several studies have reported that marginal discrepancy values greater than 120 μm are clinically unacceptable [ 9 11 , 17 , 18 ]. In the present study, no specimen showed a mean marginal discrepancy value greater than 120 μm; therefore, all methods were found to be successful in terms of marginal fit [ 21 , 22 ].…”
Section: Discussionmentioning
confidence: 99%
“…Zirconia unites all of the positive characteristics of ceramics, although it has limited esthetics due to its high opacity. Noritake Alliance (Noritake Dental Supply Co. Ltd., Japan) is one of the CAD/CAM systems capable of making production from zirconia blocks containing 94.4% ZrO 2 and 5.4% Y 2 O 3 [ 15 17 ].…”
Section: Introductionmentioning
confidence: 99%