Effect of GIC Neutral Blocking Devices (NBDs) on Power Network Ferroresonance in Malaysia

Abstract: Geomagnetic disturbance (GMD) arises during space weather and solar activity can result in geomagnetically induced current (GIC) flow in the grounded power transformers in the power network. This GIC may cause half-cycle saturation of transformers and lead to severe damage or blackout. To block the GIC flow into the power transformers, the neutral blocking devices (NBDs) based on capacitor banks are often installed in the neutral ground paths of transformers to mitigate the GIC. However, the high voltage (HV) … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2
2

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 26 publications
0
2
0
Order By: Relevance
“…The review of previous studies has shown that GMD effects can extend to power grids located in low latitudes as well and are not limited to high and mid-latitudes [10]. Therefore, we have maa de few GIC analyses on the power network in Malaysia since it is located close to the equatorial electrojet (EEJ) [9,11,12]. In [9], we have analysed the GIC impacts on saturation of four high voltage (HV) transformers types available in the Malaysian power grid using AC analysis and proposed proper GIC blocking devices to mitigate the related impacts.…”
Section: Figure 2 Magnetizing Current Of Power Transformer Under Norm...mentioning
confidence: 99%
See 1 more Smart Citation
“…The review of previous studies has shown that GMD effects can extend to power grids located in low latitudes as well and are not limited to high and mid-latitudes [10]. Therefore, we have maa de few GIC analyses on the power network in Malaysia since it is located close to the equatorial electrojet (EEJ) [9,11,12]. In [9], we have analysed the GIC impacts on saturation of four high voltage (HV) transformers types available in the Malaysian power grid using AC analysis and proposed proper GIC blocking devices to mitigate the related impacts.…”
Section: Figure 2 Magnetizing Current Of Power Transformer Under Norm...mentioning
confidence: 99%
“…In [9], we have analysed the GIC impacts on saturation of four high voltage (HV) transformers types available in the Malaysian power grid using AC analysis and proposed proper GIC blocking devices to mitigate the related impacts. In [11], we have analysed the effects of these devices on the potential power network ferroresonance. In [12], we have performed GIC analysis on the network with respect to benchmark geoelectric fields and the effects of lower voltage systems on the calculated GIC.…”
Section: Figure 2 Magnetizing Current Of Power Transformer Under Norm...mentioning
confidence: 99%