2011
DOI: 10.1016/j.exer.2011.02.005
|View full text |Cite
|
Sign up to set email alerts
|

Effect of glucose on the stress–strain behavior of ex-vivo rabbit cornea

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
17
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 28 publications
(19 citation statements)
references
References 63 publications
2
17
0
Order By: Relevance
“…It is noteworthy that patients with proliferative, non-proliferative retinopathies and those with no diabetic retinopathies did not have significantly different corneal thicknesses. 90, 97, 98, 99, 100 In addition, a study in 100 children aged 6–17 years with type 1 DM in Romania had an increase in corneal thickness compared with an equivalent number of children of the same age, 101 and similar findings had been reported in Turkey. 96 …”
Section: Cornea Stroma and Biomechanicssupporting
confidence: 55%
“…It is noteworthy that patients with proliferative, non-proliferative retinopathies and those with no diabetic retinopathies did not have significantly different corneal thicknesses. 90, 97, 98, 99, 100 In addition, a study in 100 children aged 6–17 years with type 1 DM in Romania had an increase in corneal thickness compared with an equivalent number of children of the same age, 101 and similar findings had been reported in Turkey. 96 …”
Section: Cornea Stroma and Biomechanicssupporting
confidence: 55%
“…The present study aims to assess the relationships between the ORA and CVS metrics on one hand, and IOP and CCT on the other. The study relied on rabbit corneas (Wollensak and Iomdina, 2009), (Ni et al, 2011) similar to earlier work which found the rabbit corneas a suitable, approximate model for human corneas in mechanical property characterization studies. This is especially important in light of the need to acquire statistically significant material property data, which is difficult to obtain from human donor corneas.…”
Section: Resultsmentioning
confidence: 99%
“…The stimulus can be induced in many ways, e.g., exciting with mechanical force, 6,7 acoustic radiation force, 8 or by using a laser pulse. 9 Combining different stimuli and methods to measure the mechanical response to these stimuli, several elasticity imaging modalities have been proposed such as magnetic resonance elastography, 7,10-12 ultrasound elastography, 13,14 acoustic radiation force imaging, 15,16 and supersonic shear imaging. 8,17,18 However, all of these methods require significant amplitude of tissue stimulation in order to produce a measurable signal.…”
mentioning
confidence: 99%
“…22 Since then, several groups have been utilizing OCT to obtain the biomechanical properties of tissues. 9,[23][24][25][26] De la Torre et al have measured displacement fields with a sensitivity of 10 nm in porcine cornea ex vivo.…”
mentioning
confidence: 99%