2021
DOI: 10.1371/journal.pone.0253419
|View full text |Cite
|
Sign up to set email alerts
|

Effect of grey-level discretization on texture feature on different weighted MRI images of diverse disease groups

Abstract: Purpose Many studies of MRI radiomics do not include the discretization method used for the analyses, which might indicate that the discretization methods used are considered irrelevant. Our goals were to compare three frequently used discretization methods (lesion relative resampling (LRR), lesion absolute resampling (LAR) and absolute resampling (AR)) applied to the same data set, along with two different lesion segmentation approaches. Methods We analyzed the effects of altering bin widths or bin numbers … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 51 publications
1
5
0
Order By: Relevance
“…In this study, we investigated the repeatability measures at different steps in the analyses, the normalization process, and the RI, in addition to how they were affected by object size and imaging parameters. We report improved repeatability for both biological and printed phantoms when normalization is applied to the data ( Supplementary Figures S1 and S2 , Table 4 ), findings that are in concordance with previous studies [ 7 , 52 , 56 , 94 , 95 , 96 , 97 ]. Similarly, when normalization was applied to the data, improvements were observed for the two discretization methods (FBS and FBN).…”
Section: Discussionsupporting
confidence: 91%
See 4 more Smart Citations
“…In this study, we investigated the repeatability measures at different steps in the analyses, the normalization process, and the RI, in addition to how they were affected by object size and imaging parameters. We report improved repeatability for both biological and printed phantoms when normalization is applied to the data ( Supplementary Figures S1 and S2 , Table 4 ), findings that are in concordance with previous studies [ 7 , 52 , 56 , 94 , 95 , 96 , 97 ]. Similarly, when normalization was applied to the data, improvements were observed for the two discretization methods (FBS and FBN).…”
Section: Discussionsupporting
confidence: 91%
“…Several studies of biological phantoms have proven that the segmentation procedure may affect texture analysis; hence we chose two robust volume delineation methods: the fixed cube-shaped VOI definition and the “grow from seeds” 3D Slicer tool [ 7 , 47 ]. Figure 4 A demonstrates that the visible robust texture of the Hilbert cube is not affected by the spatial resolution when using 1 mm and 2 mm isotropic volumes.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations