2020
DOI: 10.1007/s10854-020-04475-4
|View full text |Cite
|
Sign up to set email alerts
|

Effect of halide-mixing on tolerance factor and charge-carrier dynamics in (CH3NH3PbBr3−xClx) perovskites powders

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 68 publications
1
3
0
Order By: Relevance
“…The obtained diffraction peaks are ascribed to the characteristic peaks of the tetragonal perovskite crystal system (space group: I 4/ mcm ). 25,26 This confirms that all the films prepared with the varied ratios of Mg : Pb crystallize in the perovskite structure. This also ascertains that incorporation of the Mg 2+ cation in the pristine MAPbX 3 perovskite does not significantly alter or distort the inherent perovskite structure, despite the significant difference in the ionic radii of Pb 2+ and Mg 2+ .…”
Section: Resultssupporting
confidence: 71%
“…The obtained diffraction peaks are ascribed to the characteristic peaks of the tetragonal perovskite crystal system (space group: I 4/ mcm ). 25,26 This confirms that all the films prepared with the varied ratios of Mg : Pb crystallize in the perovskite structure. This also ascertains that incorporation of the Mg 2+ cation in the pristine MAPbX 3 perovskite does not significantly alter or distort the inherent perovskite structure, despite the significant difference in the ionic radii of Pb 2+ and Mg 2+ .…”
Section: Resultssupporting
confidence: 71%
“…Differently reported for simple perovskites (ABX 3 ) where the Goldschmidt’s tolerance factor t = ( r A + r X )/√2­( r B + r X ), for double halide perovskites, the r B was obtained as the average value between r Sb 3+ and r Ag + . In mixed-anion perovskites, the parameter r X can be further described using the anionic effective radius (denoted here as r effective ) which is equal to (1 – δ) r Cl – + δ r Br – , as reported by Siddique et al to analyze the stability of mixed CH 3 NH 3 PbBr 3‑ δ Cl δ perovskites. These modifications were also inserted into the calculations of the u and t ′ factors.…”
Section: Resultsmentioning
confidence: 99%
“…The SSPL and TRPL analysis were conducted by Pico Quant Fluo Time 300 (FT-300) spectrophotometer as described in our previous work [39][40][41]. Brie y, the SSPL spectrum was measured following excitation at 306 nm with a pulsed LED excitation (PLS-300) source.…”
Section: Characterization Methodsmentioning
confidence: 99%