Effect of Heat Treatment Temperature on Hardness of Jaw Implant Produced from EDM Die-Sinking Process
M. F. R. Suharyanto,
Yani Kurniawan
Abstract:Hardness is the main problem in making jaw implants using the die-sinking EDM process. Heat treatment can increase the hardness of jaw implants resulting from the EDM process. This research investigates the influence of temperature during the heat treatment process on the hardness of jaw implants produced from the EDM process. Heat treatment uses a quenching process. The quenching temperatures used were 940, 950, and 960 ºC, while the holding time was 30 minutes. The aging temperature is 550 ºC. The research r… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.