2000
DOI: 10.1016/s0003-4975(00)02024-5
|View full text |Cite
|
Sign up to set email alerts
|

Effect of hemofiltrated whole blood pump priming on hemodynamics and respiratory function after the arterial switch operation in neonates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
25
1

Year Published

2003
2003
2014
2014

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 36 publications
(28 citation statements)
references
References 19 publications
2
25
1
Order By: Relevance
“…Because these values were not measured consistently at all sites and with a decreasing frequency during the study infusion, only limited conclusions can be drawn from these data. Consistent with previous studies, [2][3][4][5]15 the lowest mixed venous oxygen saturations and highest lactate values occurred in the first 12 hours after surgery. Although no statistically significant differences were identified between treatment groups, there was a trend toward a wider difference between arterial and mixed venous oxygen saturations at 8 and 12 hours after surgery in the placebo arm compared with those treated with high-dose milrinone (Figure 5, PϽ0.07).…”
Section: Secondary End Pointssupporting
confidence: 91%
See 1 more Smart Citation
“…Because these values were not measured consistently at all sites and with a decreasing frequency during the study infusion, only limited conclusions can be drawn from these data. Consistent with previous studies, [2][3][4][5]15 the lowest mixed venous oxygen saturations and highest lactate values occurred in the first 12 hours after surgery. Although no statistically significant differences were identified between treatment groups, there was a trend toward a wider difference between arterial and mixed venous oxygen saturations at 8 and 12 hours after surgery in the placebo arm compared with those treated with high-dose milrinone (Figure 5, PϽ0.07).…”
Section: Secondary End Pointssupporting
confidence: 91%
“…This fall in cardiac index was associated with an elevated systemic vascular resistance of Ϸ25% and a rise in pulmonary vascular resistance of nearly 40% from baseline values. Other recent reports document similar hemodynamic 3,4 and respiratory 5 findings after surgery in neonates and young infants.…”
supporting
confidence: 68%
“…These same authors suggest that this technique eliminated the initial drop in blood pressure commonly seen with initiation of CPB, reduced the incidence of postoperative edema, attenuated cardiac impairment, and reduced pulmonary dysfunction (23,24) .…”
Section: Pre-cpb Ultrafiltration Of Pump Primementioning
confidence: 99%
“…Strategies to pre-treat this blood prime to reduce adverse reactions in neonatal cardiopulmonary bypass (CPB) have been proposed [2,3]. Journois et al [3] hemofiltered the blood prime prior to initiating CPB and then replaced the removed volume with a physiological electrolyte solution.…”
Section: Introductionmentioning
confidence: 99%
“…Journois et al [3] hemofiltered the blood prime prior to initiating CPB and then replaced the removed volume with a physiological electrolyte solution. Nagashima et al [2] also hemofiltered blood prior to CPB and replaced the removed volume with a maltose-, glucose-, and electrolyte-containing solution. In both cases, the authors reported some benefit to the technique.…”
Section: Introductionmentioning
confidence: 99%