1993
DOI: 10.1016/0142-9612(93)90009-q
|View full text |Cite
|
Sign up to set email alerts
|

Effect of hirudin on platelet deposition to an artificial surface during low-stress shear flow of whole blood

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
19
0

Year Published

1997
1997
2018
2018

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(19 citation statements)
references
References 20 publications
0
19
0
Order By: Relevance
“…Although Ca 2ϩ concentration has been shown to figure prominently in the potency of small glycoprotein IIb/IIIa antagonists in platelet aggregation in platelet-rich plasma (Marciniak et al, 2001), our data indicate that Ca 2ϩ ions have little if any bearing on shearinduced platelet activation and adhesion. Another report, however, showed that blood in hirudin anticoagulant reduced (up to 50%) platelet adhesion under shear stress (Alkhamis et al, 1993). This difference may reflect the use of different systems, i.e., the use of 5680-s Ϫ1 shear rate in the previous study versus 1875-s Ϫ1 shear rate in our current article, as well as the use of different platelet adhesion plate surfaces, i.e., tetrafluoroethylene-propylene copolymer versus polystyrene in our study.…”
Section: Discussionmentioning
confidence: 99%
“…Although Ca 2ϩ concentration has been shown to figure prominently in the potency of small glycoprotein IIb/IIIa antagonists in platelet aggregation in platelet-rich plasma (Marciniak et al, 2001), our data indicate that Ca 2ϩ ions have little if any bearing on shearinduced platelet activation and adhesion. Another report, however, showed that blood in hirudin anticoagulant reduced (up to 50%) platelet adhesion under shear stress (Alkhamis et al, 1993). This difference may reflect the use of different systems, i.e., the use of 5680-s Ϫ1 shear rate in the previous study versus 1875-s Ϫ1 shear rate in our current article, as well as the use of different platelet adhesion plate surfaces, i.e., tetrafluoroethylene-propylene copolymer versus polystyrene in our study.…”
Section: Discussionmentioning
confidence: 99%
“…Several authors have investigated the role of red blood cells in platelet activation and adhesion. Alkhamis and coworkers established that red blood cells release a significant fraction of ADP which is enough to induce platelet aggregation and adhesion [29]. Valles et al [30] demonstrated that interactions between red blood cells and platelets amplify platelet reactivity.…”
Section: Discussionmentioning
confidence: 99%
“…However, the small ratio of test surface to total wetted surface by contact with blood (<40%) constitutes a handicap. The same limitation results if viscometers are used: the percentage of relevant surface is low (<50%). Furthermore, it is impossible to run parallel tests simultaneously without the use of several viscometers.…”
Section: Introductionmentioning
confidence: 94%