2010
DOI: 10.1016/j.surfcoat.2010.09.001
|View full text |Cite
|
Sign up to set email alerts
|

Effect of humid air exposure between successive helium plasma treatments on PET foils

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
6
0

Year Published

2014
2014
2018
2018

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(7 citation statements)
references
References 41 publications
1
6
0
Order By: Relevance
“…The results are shown in Figure 2. As well documented in literatures, the spectrum of the original polyester contains three peaks at 284.60, 286.10, and 288.75 eV, which may be respectively assigned to C─C/C─H, C─O (and/or C─OH) and O═C─O (and/or COOH) (Sanaee et al, 2011;Jacobs et al, 2010;Zhang and Fang, 2012). According to the content variation of each chemical component shown in Table IV, it is evident that the sub-peak at 284.6 eV decreased markedly and the sub-peaks at 286.1 and 288.75 eV increased after plasma treatment.…”
Section: Xps Analysissupporting
confidence: 55%
“…The results are shown in Figure 2. As well documented in literatures, the spectrum of the original polyester contains three peaks at 284.60, 286.10, and 288.75 eV, which may be respectively assigned to C─C/C─H, C─O (and/or C─OH) and O═C─O (and/or COOH) (Sanaee et al, 2011;Jacobs et al, 2010;Zhang and Fang, 2012). According to the content variation of each chemical component shown in Table IV, it is evident that the sub-peak at 284.6 eV decreased markedly and the sub-peaks at 286.1 and 288.75 eV increased after plasma treatment.…”
Section: Xps Analysissupporting
confidence: 55%
“…35 As a result, oxygen impurities are always present in the discharge gas, and these atoms can originate from the residual air present in the discharge chamber from the working gas impurities or from the gaseous products which the plasma desorbs (H 2 O, O 2 ) from the reactor walls or etches from the polymer surfaces. 36 SEM images (Figure 2) show a modification of the surface morphology of both helium and oxygen plasma and AgNO 3 -treated catheters compared with the reference sample. The reference sample has smoother surface morphology (Figure 2(a)).…”
Section: Resultsmentioning
confidence: 99%
“…Moreover, the change in surface topography and surface roughness can be computed by one of the surface parameter namely RMS (Root mean square) roughness value (Sanchis, Blanes, Blanes, Garcia, & Balart, 2006). Because of the polymer degradation and surface modification the surface roughness was increased and the crystalline regions will remain intact, while the amorphous regions are etched away after the plasma treatment (Jacobs et al, 2010).…”
Section: Surface Morphology Analysismentioning
confidence: 99%