2020
DOI: 10.1007/s11665-020-04906-7
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Hydrothermal Treatment Time on Microstructure and Corrosion Behavior of Micro-arc Oxidation/Layered Double Hydroxide Composite Coatings on LA103Z Mg-Li Alloy in 3.5 wt.% NaCl Solution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(10 citation statements)
references
References 17 publications
0
10
0
Order By: Relevance
“…In addition, the LDH diffraction peak corresponding to the (003) crystal plane was marginally offset towards lower angles, compared with our previous study. [ 35 ]…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…In addition, the LDH diffraction peak corresponding to the (003) crystal plane was marginally offset towards lower angles, compared with our previous study. [ 35 ]…”
Section: Resultsmentioning
confidence: 99%
“…In addition, the LDH diffraction peak corresponding to the (003) crystal plane was marginally offset towards lower angles, compared with our previous study. [35] To characterize the specific distribution of each element in the LDH nanosheet, a highly magnified SEM image corresponding to region A from Figure 3e, is shown in Figure 4a. Accordingly, the electronic elemental mapping images are shown in Figure 4b-g.…”
Section: Surface Morphology and Chemical Composition Of The Differementioning
confidence: 99%
See 1 more Smart Citation
“…The correlation between the hydrothermal treatment time and the corrosion performance of LDH–PEO composite coating formed on Mg–Li alloy was examined by Zhang et al [ 90 ]. After the deposition of the coatings on Mg–Li alloy samples via PEO utilizing an electrolyte composed of NaOH, Na 2 SiO 3 ·9H 2 O, and NaF, the coated samples were placed in an aqueous solution Al(NO 3 ) 3 ·9H 2 O for 12, 18, and 24 h at 363 K. NaOH was added to adjust the pH value to be 12.4.…”
Section: Corrosion Performance Of Ldh/anodic Film Compositesmentioning
confidence: 99%
“…43,44 The interlaminar stresses are maximum between those layers with the greatest ply orientation angle difference, which creates large delamination among plies in this area. [45][46][47][48][49] Delamination causes the impactor to rebound. If the penetration appears, then the damaged area is the size of the impactor diameter.…”
Section: Impact Damage In Carbon Fiber-reinforced Compositesmentioning
confidence: 99%