2020
DOI: 10.1177/0954406220973055
|View full text |Cite
|
Sign up to set email alerts
|

Effect of incidence angle on cavity blockage and flow stability in the net positive suction head drop of mixed-flow pumps

Abstract: The cavitation is an inevitable factor in pumps used in the whole industry, which is a major cause of energy loss and mechanical breakdown. In this study, the cavitation phenomena at the design flow rate were numerically analyzed for two pumps with different incidence angles. The design flow rate for both models was located near the best efficiency point (BEP). The incidence angle was determined with the impeller inlet diameter and the blade angle. A pump with a smaller incidence angle consistently showed a st… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 56 publications
0
3
0
Order By: Relevance
“…In the other three sets, the flow patterns near the blade LE were slightly deformed, and it seems that the thickness (blockage) of the vapor decreased in the tangential direction as the ER increased. In Figure 4, despite the decrease in inlet pressure, the reason why the head drop was delayed in the larger ER set can be considered because the flow was able to pass near the LE with less obstruction due to the thinner vapor [14,15]. Meanwhile, the single-passage (shown in Figure 2) was rotationally copied as if it is a full-passage, so that the limiting streamline appears to be broken at each periodic boundary.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In the other three sets, the flow patterns near the blade LE were slightly deformed, and it seems that the thickness (blockage) of the vapor decreased in the tangential direction as the ER increased. In Figure 4, despite the decrease in inlet pressure, the reason why the head drop was delayed in the larger ER set can be considered because the flow was able to pass near the LE with less obstruction due to the thinner vapor [14,15]. Meanwhile, the single-passage (shown in Figure 2) was rotationally copied as if it is a full-passage, so that the limiting streamline appears to be broken at each periodic boundary.…”
Section: Resultsmentioning
confidence: 99%
“…These patterns tend to be consistent with the description in Figure 5. As a possibility of further research on this study, the tendency at the off-design flow rates needs to be analyzed, and the thickness (blockage) of the vapor can be quantified [14] to link with the characteristics of the head drop. In addition, in Figure 4, the ER0 set repeated decrease and increase in the head at the range 𝜎 < 1.0 with a peak just before the 3% head drop, and the ER1 set obtained a sudden decrease in the head at the point 𝜎 ≈ 0.6, in this study.…”
Section: Resultsmentioning
confidence: 99%
“…First, the numerical results were validated through experimental tests in the Korea Institute of Industrial Technology (KITECH), Korea [10]. The international standards for pump tests, ISO 5198 and ANSI/HI 1.6 [11,12], had been fully applied to the closed-loop system.…”
Section: Resultsmentioning
confidence: 99%