2014
DOI: 10.1016/j.ijheatmasstransfer.2014.06.078
|View full text |Cite
|
Sign up to set email alerts
|

Effect of inclination during condensation inside a square cross section minichannel

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0
1

Year Published

2014
2014
2023
2023

Publication Types

Select...
7
1
1

Relationship

2
7

Authors

Journals

citations
Cited by 51 publications
(11 citation statements)
references
References 23 publications
0
10
0
1
Order By: Relevance
“…Da Riva and co-workers (Da Riva and Del Col, 2009Da Riva et al, 2010aDel Col et al, 2014) conducted a series of extensive numerical studies on annular flow condensation of R134a in a 1 mm inner diameter horizontal minichannel. In all of their studies, they adopted a steady threedimensional VOF model to analyse the influence of gravity, turbulence and surface tension on the flow.…”
Section: Experimental and Modelling Studies In Simplified Geometriesmentioning
confidence: 99%
“…Da Riva and co-workers (Da Riva and Del Col, 2009Da Riva et al, 2010aDel Col et al, 2014) conducted a series of extensive numerical studies on annular flow condensation of R134a in a 1 mm inner diameter horizontal minichannel. In all of their studies, they adopted a steady threedimensional VOF model to analyse the influence of gravity, turbulence and surface tension on the flow.…”
Section: Experimental and Modelling Studies In Simplified Geometriesmentioning
confidence: 99%
“…3, де значення коефіцієнтів тепловіддачі майже однакові за низьких значень масових швидкостей G, які становлять -50, 100 і 150 кг/(м 2 с). Автори [4] посилаються на роботи [7], [12], у яких також зауважено, що значення коефіцієнтів тепловіддачі є фактично рівними за низьких масових швидкостей G = 100 і G = 200 кг/(м 2 с).…”
Section: рисунок 2 -залежність коефіцієнтів тепловіддачі unclassified
“… Da Riva and Del Col 31 Numerical Circular 1 mm ID minichannel R134a Horizontal and vertical downflow T sat = 40 °C T wall = 30 °C G = 100, 800 kg m −2 s −1 x = 0.4–1 Numerical simulations of FWC inside a circular channel by means of VOF method At G = 100 kg m −2 s −1 , HTCs obtained in the horizontal configuration nearly doubles the one in vertical downflow due to stratification effects. Del Col et al 21 Experimental and analytical Square channel with 1.23 mm hydraulic diameter R134a, R32 Horizontal, vertical and inclined (downflow and upflow) T sat = 40 °C G = 100–390 kg m −2 s −1 x = 0.2–0.9 HTC measurements Whatever the fluid, the effect of the channel inclination on the condensation HTC becomes noteworthy in downflow, at x < 0.6 and mass velocities lower than a critical value ( G crit = 150 kg m −2 s −1 for R134a, G crit = 200 kg m −2 s −1 for R32). By applying the Buckingham theorem, a criterion is developed to predict the mass velocity at which the channel inclination starts to affect FWC.…”
Section: Introductionmentioning
confidence: 99%
“…Such methods are highly instrumental in the design of thermal management systems in aircraft and spacecraft avionics. Among them, Del Col et al 21 developed a dimensionless correlation for predicting the critical mass velocity at which the effect of inclination starts to appear during condensation inside tubes. The dimensionless inclination parameter Y* (Eq.…”
Section: Introductionmentioning
confidence: 99%