2008
DOI: 10.3844/ajeassp.2008.100.103
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Inner Diameter and Inclination Angles on Operation Limit of Closed-Loop Oscillating Heat-Pipes with Check Valves

Abstract: This research was to study the effect of inner diameter and inclination angles on operation limit of a closed loop oscillating heat pipes with check valves (CLOHP/CV). A set of CLOHP/CV was made of copper tubes in combination of following dimension: 1.77 and 2.03 mm inside diameter: 10 turn, with R123 was used as the working fluid. The working fluid was filled in the tube at the filling ratio of 50%. The inclination angles were 0, 20, 40, 60, 80 and 90° with 5 equal lengths for evaporator, adiabatic and conden… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2010
2010
2017
2017

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 6 publications
0
7
0
Order By: Relevance
“…Without this pumping action, the device will operate as a solid bar conducting heat from one end to another. Characterization of thermal performance in multi-loop PHPs has been reported in few experimental investigations done by Cai [5], Charoensawan et al [6], Khandekar [7,8] and Meena et al [9]. Earlier, sensible heat transfer was thought of as the main reason of it which was shown by Groll [10], Nisho et al [11] and Shafi et al [12].…”
Section: Introductionmentioning
confidence: 94%
“…Without this pumping action, the device will operate as a solid bar conducting heat from one end to another. Characterization of thermal performance in multi-loop PHPs has been reported in few experimental investigations done by Cai [5], Charoensawan et al [6], Khandekar [7,8] and Meena et al [9]. Earlier, sensible heat transfer was thought of as the main reason of it which was shown by Groll [10], Nisho et al [11] and Shafi et al [12].…”
Section: Introductionmentioning
confidence: 94%
“…Meena et al [7] in 2008 used check valve operated closed loop oscillating heat pipes (CLHOP-CV) made up of copper tubes with R123 as working fluid to study the effect of different tilt angles and internal diameters. The fliing ratio inside the evaporator section was fixed at 50% and lengths of all 3 sections of heat pipe were same.…”
Section: Study Of Heat Pipes At Differentmentioning
confidence: 99%
“…[3], Zhang [4] and Rama Narasimha et al [12]. Characterization of thermal performance in multi-loop PHPs has been investigated by Cai [5], Charoensawan [6], Khandekar [7,8] and Meena et al [9]. Results on thermal performance of single loop PHP are also investigated by Rama Narasimha et al [10,11].…”
Section: Introductionmentioning
confidence: 95%