2020
DOI: 10.1002/bem.22302
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Intermittent ELF MF on Umbilical Cord Blood Lymphocytes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 33 publications
1
5
0
Order By: Relevance
“…The results of 25 experiments described within this work are still in good correlation with previous works of authors [19,20], and other research groups [21,22], which point to the selective response of biological systems to the application of external ELF MF. Simply, if the combination of ELF-MF parameters does not fulfill certain specific conditions, the biological reaction would be weak, or would not occur at all.…”
Section: Discussionsupporting
confidence: 89%
“…The results of 25 experiments described within this work are still in good correlation with previous works of authors [19,20], and other research groups [21,22], which point to the selective response of biological systems to the application of external ELF MF. Simply, if the combination of ELF-MF parameters does not fulfill certain specific conditions, the biological reaction would be weak, or would not occur at all.…”
Section: Discussionsupporting
confidence: 89%
“…They have provided basic information on the possible biological effects of EMF exposure to living systems. There are few studies focused on the acute or chronic EMF exposure in IF range and its consequence on human health at cellular level in vitro [45][46][47]. Therefore, the investigation of potential adverse or cumulative EMF effect is quite challenging and precise epidemiological studies are needed to confirm the possible negative effects of EMF exposure to humans [15].…”
Section: Discussionmentioning
confidence: 99%
“…The E-field induced in the cell culture medium by the MF generated by the developed coil is in the order of 10 −4 V•m −1 . The reported threshold for an E-field to elicit a biological effect is estimated to be around 10 −4 V•m −1 for neutrophil cells [8] and used in research into umbilical cord blood lymphocytes [40]. Thus, it is questionable if the EF generated by the new exposure system can be neglected, and the results obtained for biocompatibility studies can be referred to be caused by the MF.…”
Section: Numerical Simulations Of Exposure Systemmentioning
confidence: 99%
“…where q is the electric charge of the target ion, m is the molecular mass of the target ion, and B DC is the value of static magnetic flux density-the geomagnetic field in this case. The target is calcium ion 40 Ca 2+ with a cyclotron frequency of 29.89 Hz. According to the IPR, the maximal biological effect should be reached at the B AC /B DC ratio of 1.8.…”
Section: Cell Electromagnetic Biocompatibility Experimentsmentioning
confidence: 99%