Effect of mechanical assistance of the systemic ventricle in single ventricle circulation with cavopulmonary connection

Abstract: Background Previous attempts to support the single ventricle circulation mechanically have suggested that a custom-built assist device is needed to push rather than pull through the pulmonary circulation. We hypothesized that using a conventional ventricular assist device, with or without conversion of a total cavopulmonary connection to a bidirectional Glenn cavopulmonary connection would allow assistance by pulling blood through the circuit and improve cardiac index (CI). Methods Cavopulmonary connections … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(18 citation statements)
references
References 21 publications
0
17
1
Order By: Relevance
“…In all four patients in this series, the CPP was observed to decrease following VAD implantation, in conjunction with a decrease in the BNP. In an animal model studying the effect of mechanical assistance of the systemic ventricle in cavopulmonary connection with a centrifugal flow pump, Sinha et al demonstrated that improvement in cardiac index was accompanied by a decrease in the mean pulmonary artery pressure and left atrial pressure, suggesting that decompression of the systemic circulation was transmitted to the cavopulmonary circuit .…”
Section: Discussionmentioning
confidence: 77%
See 1 more Smart Citation
“…In all four patients in this series, the CPP was observed to decrease following VAD implantation, in conjunction with a decrease in the BNP. In an animal model studying the effect of mechanical assistance of the systemic ventricle in cavopulmonary connection with a centrifugal flow pump, Sinha et al demonstrated that improvement in cardiac index was accompanied by a decrease in the mean pulmonary artery pressure and left atrial pressure, suggesting that decompression of the systemic circulation was transmitted to the cavopulmonary circuit .…”
Section: Discussionmentioning
confidence: 77%
“…Based on the experimental work of Sinha et al, some degree of decreased oxygen saturation and arterial oxygen tension may be encountered in assisted patients with cavopulmonary connections. However, the augmentation of cardiac output by the VAD will offset the desaturation resulting in greater tissue oxygen delivery . Inadequate systemic oxygenation caused by impaired lung function can also be addressed by transitioning to ECMO.…”
Section: Discussionmentioning
confidence: 96%
“…Conversely, there will also be an increased flow of deoxygenated blood through the inferior vena cava (IVC). The summation has been shown in an experimental model to lead to increased oxygen delivery (23). Additionally, in case reports, it leads to improved hemodynamics (24,25).…”
Section: Second Stagementioning
confidence: 94%
“…The pump has low priming volume of 32 mL and is able to support a wide range of patient sizes. The RotaFlow was approved by the FDA in 2000 and is approved for up to 6 h of LV support . The device has achieved the CE Mark in Europe for up to 30 days.…”
Section: Clinically Used Devicesmentioning
confidence: 99%
“…This pump is used frequently in ECMO circuits. Sinha et al have employed the RotaFlow in an animal model of SV physiology to compare MCS of the Fontan versus the bidirectional Glenn shunt. MCS in these configurations augmented improved cardiac index, but there was a decrease in the mean pulmonary arterial pressure and left atrial pressure.…”
Section: Clinically Used Devicesmentioning
confidence: 99%