2020
DOI: 10.1111/joor.13097
|View full text |Cite
|
Sign up to set email alerts
|

Effect of peri‐implant bone resorption on mechanical stress in the implant body: In vivo measured load‐based finite element analysis

Abstract: Dental implant treatment has been widely accepted and commonly used in prosthodontic treatment for missing teeth. However, there are increasing number of studies of peri-implantitis and its potential association with fracture of the implant body. 1-3 Compared to fracture of the screws, fracture of the implant can be a more serious clinical issue. One of the causes of implant fracture is metal fatigue due to stress concentration in the implant. Previous research has suggested that unfavourable stress distributi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
19
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 27 publications
(19 citation statements)
references
References 21 publications
0
19
0
Order By: Relevance
“…Bone resorption is one of the key factors affecting the success of implantation [24]. The higher that the stress concentration occur in the bone around the implant is, the higher the risk of bone resorption is [25].…”
Section: Discussionmentioning
confidence: 99%
“…Bone resorption is one of the key factors affecting the success of implantation [24]. The higher that the stress concentration occur in the bone around the implant is, the higher the risk of bone resorption is [25].…”
Section: Discussionmentioning
confidence: 99%
“…A piezoelectric transducer is a kind of transducer that uses the piezoelectric effect of a piezoelectric material to convert the measured pressure into an electric signal. Its sensitive element is made of piezoelectric material (Bing et al, 2020). Piezoelectric materials in piezoelectric sensors generally include piezoelectric crystals (i.e., quartz crystals), piezoelectric ceramics, and polymer piezoelectric materials (González et al, 2016).…”
Section: Piezoelectric Transducermentioning
confidence: 99%
“…The presence of an adequate crestal bone level has been considered an important clinical determinant for the longterm success of implant treatments 1-3 because loss of bone from the peri-implant ridge will significantly affect the biomechanical anchorage of the prosthesis and may compromise treatment longevity. 4 Implants with different cervical designs and platforms have been proposed to maintain the health and quantity of periimplant tissues. Platform switching, where the implant diameter is greater than the abutment diameter, was first described by Lazzara and Porter in 2006.…”
mentioning
confidence: 99%