Effect of plenum chamber obstructions on data center performance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 54 publications
(7 citation statements)
references
References 15 publications
0
7
0
Order By: Relevance
“…The focus has been on improving thermal performance by maximizing cold capacity and preventing cold leakage and consumption. However, there has been no investigation into the effect of installing deflectors and fan floors, as noted in the cited sources [5][6][7][8][9][10][11][12][13][14][15][16][17]. This paper focuses on improving the thermal performance of a data center by means of these two methods to increase airflow at the front end, balancing the airflow between the front-end cabinets and the back-end cabinets to achieve a uniform temperature distribution.…”
Section: Fan Floormentioning
confidence: 99%
See 1 more Smart Citation
“…The focus has been on improving thermal performance by maximizing cold capacity and preventing cold leakage and consumption. However, there has been no investigation into the effect of installing deflectors and fan floors, as noted in the cited sources [5][6][7][8][9][10][11][12][13][14][15][16][17]. This paper focuses on improving the thermal performance of a data center by means of these two methods to increase airflow at the front end, balancing the airflow between the front-end cabinets and the back-end cabinets to achieve a uniform temperature distribution.…”
Section: Fan Floormentioning
confidence: 99%
“…et al [6] studied the impact of closed hot and cold aisles and different air-conditioning placements on the thermal environment and air distribution of a data room and showed that the optimization effect of closed hot aisles was better than that of closed cold aisles. Fulpagare, Y. et al [7] investigated the impact of obstacles under the air-supply floor on the cooling performance of a server room through CFD simulation. They found that obstacles such as ducts under the floor can impede airflow by up to 80%.…”
Section: Introductionmentioning
confidence: 99%
“…The flow rate increases with the augmentation of pressure difference. 25,26 The suitable and uniform pressure difference is the precondition to meet the cold air supply for cabinets. Figure 19 describes the airflow distribution of each porous tiles (1#-11#) in the cold aisles.…”
Section: Tile Exit Flow Ratesmentioning
confidence: 99%
“…In the lower space, the structure parameters of plenum, such as the plenum height, [18][19][20][21][22] floor perforation rate, 18,23,24 the layout of cables and pipes 23,25,26 and the adoption of new structures 22,27,28 in the plenum are widely investigated. Schmid 23 and Fakhim 26 studied the effect of the layout of cables and pipes in the plenum on airflow from the perforated tiles, the results indicated that reasonable layout effectively enhanced the uniformity of airflow exiting from perforated tiles and reduced the rack inlet temperatures significantly.…”
mentioning
confidence: 99%
“…Wang et al [3] studied the law of static pressure distribution in plenum chamber without barriers using the model experiment method. Fulpagare et al [4] investigated the effect of obstructions on the flow rate of a plenum chamber.And it showed that the placement of obstacles in the plenum chamber was an important factor in the performance of the air conditioning. Nada et al [5] investigated the effect of the depth of the plenum chamber on the air flow characteristics and thermal performance.…”
Section: Introductionmentioning
confidence: 99%