2011
DOI: 10.1016/j.ijggc.2011.08.012
|View full text |Cite
|
Sign up to set email alerts
|

Effect of quenching temperature on the performance of poly(vinylidene fluoride) microporous hollow fiber membranes fabricated via thermally induced phase separation technique on the removal of CO2 from CO2-gas mixture

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
18
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 61 publications
(18 citation statements)
references
References 34 publications
0
18
0
Order By: Relevance
“…Thermally induced phase separation (TIPS) method was used for this purpose (Rahbari-Sisakht, M. et al, 2014;Ghasem et al, 2011Ghasem et al, , 2012Ghasem et al, , 2013. The dope solution was prepared and extruded at temperature of 170 C. The spinning conditions are given in Table 2.…”
Section: Preparation Of Hollow Fiber Membrane Modulementioning
confidence: 99%
“…Thermally induced phase separation (TIPS) method was used for this purpose (Rahbari-Sisakht, M. et al, 2014;Ghasem et al, 2011Ghasem et al, , 2012Ghasem et al, , 2013. The dope solution was prepared and extruded at temperature of 170 C. The spinning conditions are given in Table 2.…”
Section: Preparation Of Hollow Fiber Membrane Modulementioning
confidence: 99%
“…The exact details of fabrication were presented and discussed in great details in our previous studies (Ghasem et al, 2012(Ghasem et al, , 2011Rahim et al, 2014). By using homemade membranes, shell and tube type modules were constructed using Perspex tube as shell (transparent) and hollow fiber membranes as tubes.…”
Section: Preparation Of Hollow Fiber Membrane Modulementioning
confidence: 99%
“…The inner surface contact angle was measured since the liquid was made to flow through the lumen side of membrane in absorption/stripping experiments. The details of contact angle measurement were discussed in details in our previous paper (Ghasem et al, 2012(Ghasem et al, , 2011Rahim et al, 2014). …”
Section: Contact Angle Measurementmentioning
confidence: 99%
See 1 more Smart Citation
“…Compared to NIPS method, the thermally induced phase separation (TIPS) method has more advantages as follows: the parameters controlled in TIPS process are fewer and the process can be completed more stably and continuously; membrane porosity and strength are higher. There are many literature concerning about TIPS method [1][2][3][4]. The selection of diluent used in TIPS method is essentially difficult to find blending polymers in TIPS process [17,18].…”
Section: Introductionmentioning
confidence: 99%