1998
DOI: 10.1016/s0021-9673(97)01067-4
|View full text |Cite
|
Sign up to set email alerts
|

Effect of radial gradient of temperature on the performance of large-diameter high-performance liquid chromatography columns

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2002
2002
2021
2021

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 37 publications
(10 citation statements)
references
References 13 publications
0
10
0
Order By: Relevance
“…The efficiency is increased from N=3950 to N=8800 with SD=0. 15 The average asymmetry factor, measured at 10% of the peak height, was reduced from 1.7 with the original injector, which is acceptable, to 1.07 with the AIS, which is good.…”
Section: Analytical Injectionsmentioning
confidence: 90%
See 1 more Smart Citation
“…The efficiency is increased from N=3950 to N=8800 with SD=0. 15 The average asymmetry factor, measured at 10% of the peak height, was reduced from 1.7 with the original injector, which is acceptable, to 1.07 with the AIS, which is good.…”
Section: Analytical Injectionsmentioning
confidence: 90%
“…It has been shown by Farkas [12] that "the slurry packed columns are heterogeneous, with a wall region in which the column permeability is lower than in the core region". Dapremont [15] and Brandt [16,17] have, moreover, shown the existence in the column of a temperature gradient caused by the flow past the particles. The higher temperature in the core of the column reduces the viscosity of the solvent and so increases its speed.…”
Section: Introductionmentioning
confidence: 99%
“…This results in a separation using a flow rate of 510.4 l h −1 and a load of 21.3 g injection −1 . Typically, as the scale increases, the performance improves as the extra column effects and the column internal thermal radial gradient become less important, 57 providing that the inlet and outlet column distributors are designed properly. …”
Section: Optimization and Scale-up Considerationsmentioning
confidence: 99%
“…57,65 Because porous silica beds are notoriously poor heat conductors, a gradient of temperature can be generated inside the column if the eluent and the column jackets are set at different temperatures. Because the retention of a molecule is strongly affected by temperature, a radial and axial gradient of temperature can result in a nonhomogeneous band distribution inside the column.…”
Section: Effect Of Temperaturementioning
confidence: 99%
“…[3,12,13] deal with the influence of temperature gradients, [2,14] with inhomogeneous chromatographic beds and [5,15] with phenomena, which occur due to local maldistributions of the sample coupled with the flow field.…”
Section: Radial Effects In Hplc Columnsmentioning
confidence: 99%