2006
DOI: 10.1063/1.2194127
|View full text |Cite
|
Sign up to set email alerts
|

Effect of solvents on the chemical and physical properties of ionic polymer-metal composites

Abstract: Ionic polymer-metal composites ͑IPMCs͒ consist of a perfluorinated ionomer membrane ͑usually Nafion® or Flemion®͒ plated on both faces with a noble metal such as gold or platinum and neutralized with a certain amount of counterions that balance the electrical charge of anions covalently fixed to the backbone ionomer. IPMCs are electroactive materials with potential applications as actuators and sensors. Their electrical-chemical-mechanical response is dependent on the cations used, the nature and the amount of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
97
0

Year Published

2006
2006
2013
2013

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 99 publications
(102 citation statements)
references
References 15 publications
5
97
0
Order By: Relevance
“…With crown ethers, on the other hand, we discovered experimentally 6 that there may be a remarkable qualitative change in the actuation, depending on the cation and the crown ether. For example, Nafion-based IPMCs in Li + -form show only a small relaxation towards the cathode with water, but with ethylene glycol, glycerol, or 12-Crown-4 they show extensive back relaxation towards the cathode after an initial small actuation towards the anode.…”
Section: B Actuation Of Ipmcsmentioning
confidence: 99%
See 3 more Smart Citations
“…With crown ethers, on the other hand, we discovered experimentally 6 that there may be a remarkable qualitative change in the actuation, depending on the cation and the crown ether. For example, Nafion-based IPMCs in Li + -form show only a small relaxation towards the cathode with water, but with ethylene glycol, glycerol, or 12-Crown-4 they show extensive back relaxation towards the cathode after an initial small actuation towards the anode.…”
Section: B Actuation Of Ipmcsmentioning
confidence: 99%
“…6 For solvents such as glycerol or crown ethers, the sensitivity of our measurement devices was insufficient to discern in certain cases the necessary signals from that of the background noise. So for the purpose of modeling, a value within the measured range is used for the effective capacitance.…”
Section: E Response Upon Shortingmentioning
confidence: 99%
See 2 more Smart Citations
“…Beyond that, though, there have been a number of models based on different physical phenomena that can closely match experimental data. The models that provide a direct comparison between experiment and theory can generally be separated into phenomenological models based on curvefits of experimental data [6][7][8][9] and physics-based models that attempt to predict the material response from governing equations.…”
Section: Introductionmentioning
confidence: 99%