1998
DOI: 10.1205/026387698525577
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Sparger Design and Height to Diameter Ratio on Fractional Gas Hold-up in Bubble Columns

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

7
65
1

Year Published

2001
2001
2016
2016

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 105 publications
(73 citation statements)
references
References 11 publications
7
65
1
Order By: Relevance
“…23, in which the BSDs (U G ¼0.0111 m/s) at h ¼2.4 m and the BSD at h¼1.4 m are compared: the BSDs are similar, confirming that the flow is developed. This agrees with the literature: according to Thorat et al (1998), at h/d c 45, the holdup profile is fully developed (then, the BSD is approximately constant) and, in this case, the images taken at h¼1.4 m correspond to h/d c ¼ 5.83. The main difference in the counter-current mode (Fig.…”
Section: Image Analysissupporting
confidence: 92%
See 1 more Smart Citation
“…23, in which the BSDs (U G ¼0.0111 m/s) at h ¼2.4 m and the BSD at h¼1.4 m are compared: the BSDs are similar, confirming that the flow is developed. This agrees with the literature: according to Thorat et al (1998), at h/d c 45, the holdup profile is fully developed (then, the BSD is approximately constant) and, in this case, the images taken at h¼1.4 m correspond to h/d c ¼ 5.83. The main difference in the counter-current mode (Fig.…”
Section: Image Analysissupporting
confidence: 92%
“…Herein, we compare our results (in the batch mode) with a set of experimental studies with similar column diameters and sparger designs (Akita and Yoshida, 1973;Fair et al, 1962;Gopal and Sharma, 1983;Kawase and Moo-Young, 1987a;Otake et al, 1981;Reilly et al, 1986;Sada et al, 1984;Schumpe and Grund, 1986;Thorat et al, 1998;Ying et al, 1981;Yoshida and Akita, 1965). At first, we compare the data in the low U G range (Fig.…”
Section: Comparison With Data From the Literaturementioning
confidence: 99%
“…Most traditional design of bubble column reactors favors a high height-to-diameter ratio (L/D) to allow system hydrodynamics to reach a fully developed state [1][2][3][4][5]. The gas distributor region is generally ignored in the scale-up considerations.…”
Section: Introductionmentioning
confidence: 99%
“…Most of the studies available focus on the effect of gas distributor design on the performance of shallow bubble column [3,[12][13][14][15][16]. However, there are mixed reports on the effect of static liquid height on bubble column performance.…”
Section: Introductionmentioning
confidence: 99%
“…In the heterogeneous flow regime, the drift flux analysis has been recommended by many investigators to estimate gas holdup (Saxena et al, 1991;Thorat et al, 1998;Zahradnik et al, 1999) due to its simplicity.…”
Section: Gas Holdup Modelsmentioning
confidence: 99%