2017
DOI: 10.1117/12.2254999
|View full text |Cite
|
Sign up to set email alerts
|

Effect of spatio-energy correlation in PCD due to charge sharing, scatter, and secondary photons

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
24
0

Year Published

2017
2017
2018
2018

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 16 publications
(24 citation statements)
references
References 0 publications
0
24
0
Order By: Relevance
“…Several studies have been published on how to model the frequency‐dependent detective quantum efficiency of photon‐counting detectors, but these studies do not take energy information into account. At the same time, the impact of detector nonidealities on spectral imaging tasks has been studied by several authors . However, these publications only study the zero‐spatial‐frequency performance and do not investigate the frequency‐dependent spectral performance.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Several studies have been published on how to model the frequency‐dependent detective quantum efficiency of photon‐counting detectors, but these studies do not take energy information into account. At the same time, the impact of detector nonidealities on spectral imaging tasks has been studied by several authors . However, these publications only study the zero‐spatial‐frequency performance and do not investigate the frequency‐dependent spectral performance.…”
Section: Introductionmentioning
confidence: 99%
“…At the same time, the impact of detector nonidealities on spectral imaging tasks has been studied by several authors. [21][22][23][24][25][26][27] However, these publications only study the zero-spatial-frequency performance and do not investigate the frequency-dependent spectral performance. Shikhaliev et al 28 studied the effect of characteristic x rays on the spectrum shape and on the spatial resolution.…”
Section: Introductionmentioning
confidence: 99%
“…As indicated by Ref. , the magnitude of the adverse effect of cross‐talk strongly depends on the applications. The goodness of the soft tissue contrast is governed by the goodness of the total counts; thus, studying counts above a single threshold was sufficient and necessary.…”
Section: Discussionmentioning
confidence: 93%
“…When a photon deposits signal that is shared between multiple pixels, the information is blurred, reducing its high‐frequency signal. The detective quantum efficiency is therefore reduced in high spatial frequency tasks . Photons arriving at a pixel will deposit charge in neighboring pixels.…”
Section: Methodsmentioning