2020
DOI: 10.1111/ggr.12357
|View full text |Cite
|
Sign up to set email alerts
|

Effect of the Dry Ashing Method on Cadmium Isotope Measurements in Soil and Plant Samples

Abstract: A dry ashing method is commonly used to remove organic material from samples prior to geochemical analysis. In the course of this study, the Cd isotope ratios of a series of soil and plant reference materials and samples were studied to evaluate the effect of the dry ashing method on measurement results of Cd isotope ratios. The samples were pre‐treated using the dry ashing method and high‐pressure bomb for comparison. The results show that the digestion using high‐pressure bombs did not lead to Cd loss, but u… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 57 publications
3
3
0
Order By: Relevance
“…Their δ 114/110 Cd values (relative to NIST SRM 3108) were −1.33‰ ± 0.05‰ (n = 77) and −0.69‰ ± 0.05‰ (n = 91), respectively. These values agree with previously reported data, 37,38 and the measurement precision was better than ±0.05‰ (2SD). The δ 114/110 Cd values (relative to NIST SRM 3108) of four types of soil materials, NIST 2710, NIST 2710a, NIST 2711, and NIST 2711a, also agree with previously published values.…”
Section: Plant and Soil Analysissupporting
confidence: 93%
See 2 more Smart Citations
“…Their δ 114/110 Cd values (relative to NIST SRM 3108) were −1.33‰ ± 0.05‰ (n = 77) and −0.69‰ ± 0.05‰ (n = 91), respectively. These values agree with previously reported data, 37,38 and the measurement precision was better than ±0.05‰ (2SD). The δ 114/110 Cd values (relative to NIST SRM 3108) of four types of soil materials, NIST 2710, NIST 2710a, NIST 2711, and NIST 2711a, also agree with previously published values.…”
Section: Plant and Soil Analysissupporting
confidence: 93%
“…111 Cd– 113 Cd double spikes were added to the sample solution and heated on a hot plate at 120 °C for 24 h to equilibrate the samples with spikes. Prior to isotopic analysis, chemical purification was performed as previously described. , Briefly, the digested sample dissolved in 6 mol L –1 HCl was loaded into the anion exchange resin AG1-X8 (200–400 meshes, Bio-Rad, USA) in thermoretractable Teflon columns. Next, 6 mol L –1 HCl, 0.3 mol L –1 HCl, and the mixture of 0.5 mol L –1 HNO 3 and 0.1 mol L –1 HBr were sequentially used to elute matrix elements, and finally, Cd was obtained with 2 mol L –1 HNO 3 .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Various digestion methods for the determination of Cd isotope ratios in a range of soil and plant materials were studied. 119 High pressure bomb digestion at 195 C for 72 h with a 1 + 3 mixture of HNO 3 and HF did not lead to Cd loss and d 114/110 Cd values for the four soil and two plant RMs tested gave reproducible results within reported values. On the other hand, dry ashing, performed at 550 C for between 12 and 24 h with 25-700 mg sample, followed by heating at 120 C for 24 h with a 1 + 3 v/v mixture of HNO 3 and HF, resulted in Cd loss and perturbation of Cd isotope ratios to varying degrees in all sample types.…”
Section: Sample Dissolution and Extractionsupporting
confidence: 53%
“…The dry ashing procedure can efficiently and quickly remove organic matter but may also result in elemental loss and potential isotopic fractionation (Li et al 2011, Lv et al 2020, Zhang et al 2018. In contrast, using the highpressure bomb has been considered as a robust procedure that does not affect U isotope measurements of geological and environmental samples (Zhang and Hu 2019).…”
Section: U Measurementmentioning
confidence: 99%