2012
DOI: 10.1016/j.ejrad.2010.11.028
|View full text |Cite
|
Sign up to set email alerts
|

Effective dose range for dental cone beam computed tomography scanners

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

11
393
1
37

Year Published

2012
2012
2015
2015

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 532 publications
(459 citation statements)
references
References 18 publications
11
393
1
37
Order By: Relevance
“…In a comparison between effective radiation dose of CBCT and Multislice CT (MSCT) scanners for dental and maxillofacial applications, effective dose values ranged from 13 to 82 lSv for CBCT and from 474 to 1160 lSv for MSCT [5]. Similar data concerning a significant decrease in radiation dose values have been reported elsewhere [4,6]. Considering the number of scans or radiographic examinations obtained in a typical ACIF procedure, from initial diagnosis through the end of treatment, it seems prudent then to limit the patient's exposure and therefore obviate the potentially deleterious effects of radiation exposure.…”
Section: Discussionsupporting
confidence: 77%
See 1 more Smart Citation
“…In a comparison between effective radiation dose of CBCT and Multislice CT (MSCT) scanners for dental and maxillofacial applications, effective dose values ranged from 13 to 82 lSv for CBCT and from 474 to 1160 lSv for MSCT [5]. Similar data concerning a significant decrease in radiation dose values have been reported elsewhere [4,6]. Considering the number of scans or radiographic examinations obtained in a typical ACIF procedure, from initial diagnosis through the end of treatment, it seems prudent then to limit the patient's exposure and therefore obviate the potentially deleterious effects of radiation exposure.…”
Section: Discussionsupporting
confidence: 77%
“…CBCT was first developed as a tool for clinical use in 1982 at the Mayo Clinic Biodynamics Research Laboratory [2]. In the intervening years, several CBCT systems have been developed for use both in the interventional suite as well as the originally intended general applications such as CT angiography [3,4].…”
Section: Introductionmentioning
confidence: 99%
“…To date, most studies concerning effective dose assessment have used thermoluminescent dosimeters (TLD) in combination with anthropomorphic phantoms 2 , 3 , 4 , 5 , 6 , 7 . The low‐dose limit of TLDs when using single exposure (0.3 mGy) 8 , 9 has been considered adequate in most applications and has, therefore, been used as the reference low‐dose limit in MOSFET uncertainty assessment in this study.…”
Section: Introductionmentioning
confidence: 99%
“…Guidelines for dental radiography are shown in Table 1. Multi-slice CT may deliver equivalent resolution from equivalent dose compared to CBCT 56 but it has also been stated CBCT can deliver reduced effective dose 57 (Table 2 58 ). Both CT and CBCT can have an adjustable Field of View (FoV).…”
Section: Ultraviolet (Uv) (Wavelength Of 10 -8 To 4 X 10 -7 M)mentioning
confidence: 99%