2023
DOI: 10.1061/ppscfx.sceng-1260
|View full text |Cite
|
Sign up to set email alerts
|

Effectiveness of Stiffeners in CFDST Columns: Comparative Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 61 publications
0
2
0
Order By: Relevance
“…Similarly, when these 6-number of Figure 1 Column classifications stiffeners are provided in outer tubes only, up to 26% increase in axial load-carrying capacity has been observed. Furthermore, in these stiffened CFDST columns, a reduction in concrete core strength has been reported (Hassan and Bhat, 2022;Liang et al, 2019;Mohammadbagheri and Shekastehband, 2020;Wang et al, 2020). In circular-circular CFDST slender columns, subjected to axial load, with stiffeners of different shapes (profiles) in the outer tube as well as in the inner tube, a 15% increase in load carrying capacity has been observed (Ghannam and Metwally, 2020).…”
Section: Introductionmentioning
confidence: 93%
See 1 more Smart Citation
“…Similarly, when these 6-number of Figure 1 Column classifications stiffeners are provided in outer tubes only, up to 26% increase in axial load-carrying capacity has been observed. Furthermore, in these stiffened CFDST columns, a reduction in concrete core strength has been reported (Hassan and Bhat, 2022;Liang et al, 2019;Mohammadbagheri and Shekastehband, 2020;Wang et al, 2020). In circular-circular CFDST slender columns, subjected to axial load, with stiffeners of different shapes (profiles) in the outer tube as well as in the inner tube, a 15% increase in load carrying capacity has been observed (Ghannam and Metwally, 2020).…”
Section: Introductionmentioning
confidence: 93%
“…Externally or internally stiffened, circular-circular CFDST columns, subjected to high temperatures (fire scenario), showed 38% increase in fire resistance/rating (Mohammadbagheri and Shekastehband, 2020). The circularcircular, stiffened CFDST, provided with 6-number of stiffeners, exhibited up to 11% increase in axial load carrying capacity, when stiffeners are provided in inner tubes only (Hassan and Bhat, 2022). Similarly, when these 6-number of Figure 1 Column classifications stiffeners are provided in outer tubes only, up to 26% increase in axial load-carrying capacity has been observed.…”
Section: Introductionmentioning
confidence: 99%